Intra-operative fractures in cementless bipolar hemiarthroplasty.

نویسندگان

  • Chung-Liang Kuo
  • Si Heng Sharon Tan
  • Haw Chou Lee
چکیده

PURPOSE To compare patients with or without intra-operative fracture during cementless bipolar hemiarthroplasty. METHODS Records of 76 men and 202 women who underwent cementless bipolar hemiarthroplasty for femoral neck fractures were reviewed. Patients with and without intra-operative fractures and patients with different types of intra-operative fractures were compared. RESULTS Two men and 22 women aged 62 to 93 (mean, 80) years sustained intra-operative fractures at the lesser trochanter (n=18), the greater trochanter (n=5), and the subtrochanter (n=1). All 18 lesser trochanteric fractures and 4 of the greater trochanteric fractures were recognised intra-operatively and managed with cerclage wiring (n=21) or conversion to cemented hemiarthroplasty with cerclage wiring (n=1). The remaining 2 fractures were recognised postoperatively on radiographs and managed conservatively or with revision surgery and cerclage wiring and plating on day 4. Intra-operative fractures correlated with female gender (p=0.03) and operative delay to optimise patients (p=0.02), whereas the fracture site correlated with the time of fracture recognition (p=0.01). Postoperatively, 5 patients were allowed partial weight bearing and 18 were instructed to mobilise with a wheelchair for at least 6 weeks. One patient died from an unrelated cause. At one year, 21 patients reported no hip pain and 2 reported minimal pain. 17 could walk with or without aids and 6 were wheelchair-bound. CONCLUSION Surgeons should be familiar with the size difference in trial and actual implants used in bipolar hemiarthroplasty in order to better estimate the extent of broaching required. In most patients with an intra-operative fracture, the one-year outcome was not compromised, despite the poorer short-term outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cemented versus cementless hemiarthroplasty for femoral neck fractures in the elderly.

PURPOSE To compare cemented versus cementless bipolar hemiarthroplasty in terms of operating time, blood loss, pain, functional outcome, morbidity, and mortality. METHODS Medical records of 207 patients aged ≥ 60 years who underwent bipolar hemiarthroplasty for displaced femoral neck fracture using a cemented (n=96) or cementless (n=111) prosthesis were reviewed. Postoperative thigh pain, amb...

متن کامل

Cementless Bipolar Hemiarthroplasty for Unstable Intertrochanteric Fractures in Elderly Patients

BACKGROUND Bipolar hemiarthroplasty for unstable intertrochanteric fractures in elderly patients is a viable option that can prevent the complications of an open reduction, such as nonunion and metal failure. This study evaluated the clinicoradiological results of cementless bipolar hemiarthroplasty for unstable intertrochanteric fractures in elderly patients. METHODS Forty hips were followed...

متن کامل

Comparative Study of Bipolar Hemiarthroplasty for Femur Neck Fractures Treated with Cemented versus Cementless Stem

PURPOSE To compare and analyze clinical and radiologic outcomes of cemented versus cementless bipolar hemiarthroplasty for treatment of femur neck fractures. MATERIALS AND METHODS A total of 180 patients aged 65 years and over older who underwent bipolar hemiarthroplasty for treatment of displaced femur neck fractures (Garden stage III, IV) from March 2009 to February 2014 were included in th...

متن کامل

Effects of teriparatide on cementless bipolar hemiarthroplasty in patients with osteoporotic femoral neck fractures

BACKGROUND For osteoporotic femoral neck fractures, suitable bone-implant stability is critical for pain relief, early return to daily activities and reduction of complications. Teriparatide (parathyroid hormone [PTH1-34]) can improve bone-implant stability in some basic studies. However it's use in osteoporotic femoral neck fractures treated by cementless hemiarthroplasties for the beneficial ...

متن کامل

Proximally coated cementless bipolar hemiarthroplasty in Dorr type C bone.

The current study was conducted to examine the clinical and radiographic outcomes of cementless bipolar arthroplasty in patients who had type C bone at the time of the procedure. A total of 87 patients (105 hips) who had type C femora and had undergone cementless bipolar hemiarthroplasty with a proximally coated cementless prosthesis for the treatment of displaced femoral neck fractures at a si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2015