Enzyme immunoassay for serum lidocaine in antiarrhythmic therapy.
نویسندگان
چکیده
We have adapted the commercially available EMIT kit [Clin. Chem. 23, 1161 (1977)] to the Gilford System 3500 Analyzer. Sample volume is 10 microliter. We compare reagent blank-corrected absorbance changes at 340 nm between 15 and 55 s for samples and a series of calibrators, and calculate results with use of a logarithmic transformation. Within-run precision (CV) for a serum pool with 4.0 mg of added lidocaine per liter was 2.7% (n = 45); day-to-day precision was 3.3% (n = 15). Analytical recoveries of 2 to 6 mg of lidocaine per liter were 90-102% (average, 97.3%). Results correlated significantly with those by a gas-chromatographic technique. No clinically significant interferences by concomitantly administered medications were observed. The procedure is rapid (42 samples per hour) and is well suited to the fast response required in monitoring lidocaine therapy. Usefulness of the assay data in the management of arrhythmias in the coronary care unit is discussed.
منابع مشابه
Enzyme immunoassay and gas--liquid chromatography compared for determination of lidocaine in serum.
Lidocaine, an anti-arrhythmic drug, was quantitated in serum by a commercially supplied enzyme immunoassay procedure. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of less than 5.0 and a between-assay coefficient of variation of less than 6.5. Regression analysis of 87 serum samples analyzed by this technique (y) and by gas-liquid chromatography (x) g...
متن کاملDETERMINATION OF SERUM CORTISOL LEVEL BY A DIREC T ENZYME IMMUNOASSAY USING PENICILLINASE AS LABEL
Serum cortisol level was measured by an enzyme immunoassay (EIA) using the enzyme penicillinase as a label without prior extraction and purification. Polyclonal antibodies were raised against cortisol-3-ortho-carboxymethyl-oxime (cortisol-3-0-CMO) conjugated to bovine serum albumin (BSA). This antibody showed a very low cross-reactivity with structurally related steroids (3.7% for corticos...
متن کاملEffects of class I antiarrhythmic drugs on mitochondrial ATPase activity in guinea pig heart preparations.
1. The effects of three class I antiarrhythmic drugs quinidine, lidocaine and lorcainide on undamaged myocardial mitochondrial ATPase [ATP: phosphohydrolase, EC 3.6.1.3] activity were evaluated in guinea pig heart preparations. 2. All three drugs inhibited the enzyme activity in a concentration-dependent fashion. 3. Lorcainide was the most potent, exerting inhibitory effects in the range of les...
متن کاملDEMONSTRATION OF LOCAL ANTITOXOPLASMIC IMMUNOGLOBULIN G PRODUCTION IN OCULAR TOXOPLASMOSIS, TRACED BY ENZYME IMMUNOASSAY OF AQUEOUS HUMOR AND SERUM
Forty patients with cataracts, as well as 40 patients with proven ocular toxoplasmosis were enrolled in this prospective clinical study. Serum IgG and aqueous IgG in both groups were measured by enzyme-linked immunosorbent assay (ELISA) and the corresponding ratios were calculated. Serum IgG/aqueous humor IgG ratio was less than 100 in the patient group and more than 100 in the control gro...
متن کاملQuantification of Human Chorionic Gonadotropin by Bovine Serum Albumin Nanoparticles
Background and Aims: Some nanoparticles can be used in immunoassays to increase sensitivity. This study aimed to evaluate a novel nano-immunoassay based on bovine serum albumin nanoparticles (BSA NPs). Materials and methods: At first, the nanostructure was synthesized, and then applied as a tag in the nano-immunoassay. Then the concentration of β-subunit of human chorionic gonadotropin ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 4 شماره
صفحات -
تاریخ انتشار 1979