High-sensitive analysis of DNA fragments by capillary gel electrophoresis using transient isotachophoresis preconcentration and fluorescence detection.

نویسندگان

  • Zhongqi Xu
  • Toshiaki Esumi
  • Natsuki Ikuta
  • Takeshi Hirokawa
چکیده

In this report aimed on further development of a high-sensitivity capillary gel electrophoresis (CGE) method for analysis of DNA fragments, we firstly explored online transient isotachophoresis (tITP) preconcentration combined with fluorescence detection (FD). The fluorescence signal (excitation: 488 nm; emission: 590 nm) was generated using the intercalating dye of ethidium bromide (EB). It was found when the leading electrolyte (LE) was injected behind the sample zone, such a special tITP mode has significant advantages to solve the bubble formation issue and to improve the analytical performance stability. Two standard DNA samples, a 50 bp DNA step ladder and the phiX174/HaeIII digest, were used to evaluate the qualitative and quantitative abilities of the tITP-FD approach. A highly diluted sample (10,000-fold in the water, e.g. the phiX174/HaeIII digest diluted from 500 microg/ml to the 50 ng/ml level) was enriched and detected; the LOD was down to 0.09 ng/ml for the 72 bp fragment, apparently improved more than 1000-fold in comparison with UV detection. Although the RSD of peak areas (n=3) was around 15.5% for the sample was electrokinetically injected, good linearity of peak area response showed that the proposed method is suitable for quantitative analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integration of rapid DNA hybridization and capillary zone electrophoresis using bidirectional isotachophoresis.

We present a method for rapid, sequence-specific detection of multiple DNA fragments by integrating isotachophoresis (ITP) based DNA hybridization and capillary zone electrophoresis (CZE) using bidirectional ITP. Our method leverages the high preconcentration ability of ITP to accelerate slow, second-order DNA hybridization kinetics, and the high resolving power of CZE to separate and identify ...

متن کامل

Sensitive determination of anions in saliva using capillary electrophoresis after transient isotachophoretic preconcentration.

A transient isotachophoresis-capillary electrophoresis (tITP-CE) system for the determination of minor inorganic anions in saliva is described. The complete separation and quantification of bromide, iodide, nitrate, nitrite, and thiocyanate has been achieved with only centrifugation and dilution of the saliva sample. In-line tITP preconcentration conditions, created by introduction of the plugs...

متن کامل

Detection of 100 aM fluorophores using a high-sensitivity on-chip CE system and transient isotachophoresis.

We present a highly sensitive capillary electrophoresis (CE) assay that combines transient, single-interface on-chip isotachophoresis (ITP) and a laser-induced confocal fluorescence detection setup. We performed experimental parametric studies to show the effects of microscope objective specifications and intensity of excitation laser on optimization of a high-sensitivity on-chip CE detection s...

متن کامل

Optimization of the Analysis of Almond DNA Simple Sequence Repeats (SSRs) Through Submarine Electrophoresis Using Different Agaroses and Staining Protocols

Simple sequence repeat (SSR markers or microsatellites), based on the specific PCR amplification of DNA sequences, are becoming the markers of choice for molecular characterization of a wide range of plants because of their high polymorphism, abundance, and codominant inheritance. Different methods have been used for the analysis of the SSR amplified fragments being submarine agarose electropho...

متن کامل

Fluorescence lifetime for on-the-fly multiplex detection of DNA restriction fragments in capillary electrophoresis.

This paper describes the first use of frequency-domain fluorescence lifetime for multiplex detection of DNA restriction fragments in capillary electrophoresis (CE). The fragments were labeled with monomeric intercalating dyes that can be excited by either the 488- or 514-nm line of an argon ion laser and have lifetimes in the range of 0.5-2.5 ns. We were able to achieve multiplex lifetime detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1216 17  شماره 

صفحات  -

تاریخ انتشار 2009