The stability and sterility of epinephrine prefilled syringe.
نویسندگان
چکیده
The commercially available auto-injector epinephrine is considerable expensive. Epinephrine prefilled syringe is an alternative treatment for anaphylaxis patients. The objective of the present study was to evaluate the stability and sterility of epinephrine prefilled syringe. Epinephrine prefilled syringe was kept in the pencil box to prevent from light exposure. The active ingredients, integrity and level of potency were measured by high-performance liquid chromatography (HPLC). The sterility was accessed by aerobic bacteria and fungi culture. The epinephrine concentration at 1, 2 and 3 months after the preparation was 101.36, 99.31 and 101.09%, respectively (acceptable range 90 - 110%). The pH was 3.17 - 3.23 (acceptable range 2.8 - 3.6). Nor-epinephrine was undetected. The cultures for bacteria and fungus were both negative. Consequently, epinephrine prefilled syringe was stable and sterile at least three month after preparation. Epinephrine prefilled syrine is an alternative low cost treatment for anaphylaxis patient.
منابع مشابه
Prefilled Syringes for Viscous Formulations
www.ondrugdelivery.com 27 In this article, Mahesh Chaubal, PhD, Senior Director, Drug Development, R&D Medical Products, Baxter Healthcare Corporation, provides a glimpse of some of the challenges faced during the development of viscous formulations of biopharmaceutical products for injection, from a formulator’s perspective, especially when the finished product is filled in a prefilled syringe...
متن کاملEtanercept (Enbrel®) alternative storage at ambient temperature
BACKGROUND Biologic disease-modifying antirheumatic drugs, including tumor necrosis factor inhibitors such as etanercept (Enbrel®), have improved outcomes for patients with rheumatic and other inflammatory diseases, with sustained remission being the optimal goal for patients with rheumatoid arthritis. Flexible and convenient treatment options, compatible with modern lifestyle, are important in...
متن کاملStability of U-500 regular insulin in prefilled syringes.
OBJECTIVE To evaluate the stability of U-500 regular insulin in prefilled syringes stored under refrigeration for up to 28 days. METHODS U-500 regular insulin was drawn up in 1 mL insulin syringes in a clean, nonsterile environment to emulate conditions of a patient's home. Samples were assayed using a stability-indicating reverse-phase high-performance liquid chromatography method immediatel...
متن کاملSPECIAL REPORT - Prefilled Syringes & Parenteral Contract Manufacturing: Improving for Flexibility & Customization
Arise in biologics and complex compounds-specifically in large-molecule drugs that require innovative injection methods-is driving the prefilled syringe market. The erosion of the blockbuster model, expiring patents, and growing competition have also increased the need for differentiation in drug delivery, while changes in demographics, particularly in the growing homecare sector, increase the ...
متن کاملThe Importance of Extractables & Leachables Testing for Injectable Drug Delivery Systems
Copyright © 2009 ONdrugDelivery Publishing Ltd 22 Suppliers of pharmaceutical packaging components and delivery devices have been working closely with the industry in an effort to provide solutions for mitigating the risk associated with extractables and leachables. This effort includes managing both the technical and regulatory aspects of the subject. The following example illustrates the chal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Asian Pacific journal of allergy and immunology
دوره 28 1 شماره
صفحات -
تاریخ انتشار 2010