Air Bubble Growth in Water
نویسندگان
چکیده
To the Editor:—I read with considerable interest the article by Benavides et al. describing experiments of air bubble growth in water during exposure to 100% nitrous oxide, 100% xenon, or 50% xenon–50% oxygen. Although the experiments were nicely conducted, they explore a physics of gas flux in an unconstrained bubble permitted to grow spherically. Importantly, this geometry has limited biologic relevance for bubbles occluding vessels in the size range they have studied. The authors have referenced our previous work on xenon transport, but they have mistakenly interpreted the findings presented therein to indicate the growth of bubbles as spheres. Rather, that study presents some simulations for bubbles that are initially spherical and just fill the vessel lumen. Such bubbles cannot grow radially because they are constrained by the vessel wall and therefore elongate during growth while maintaining a fixed curvature on the interface. This results in a much different force balance across the gas–liquid interface and, hence, a different pressure condition on the interior of the bubble from that which occurs in the case of a time-varying interfacial shape, which the authors have studied. We have described these differences in our previous theoretical and experimental studies of intravascular gas embolism. In addition, the initial internal gas content they have studied includes nitrogen, equilibrated with test solution A, but test solution B is nitrogen free. Hence, there are large gradients for nitrogen flux when the solutions are switched. We purposely avoided nitrogen as a component of either the bubble or perfusate in our predictions and considered only oxygen and xenon as the transportable species. Whereas others have studied growth of similarly unconstrained air bubbles during cardiopulmonary bypass, our work has not provided any data for direct comparisons such as the authors have made, based on the different gas constituents and the governing physics dictated by the shape constraint. I find it fascinating, however, that they have couched their results in terms of bubble diameter growth. When transferred to the volume domain, one readily sees that the spherical bubbles exposed to 100% xenon or 100% nitrous oxide had grown to more than twice their initial volume in 25 min (figs. 2 and 3) and continued growing when the solutions were switched (downward arrow). The time required for this is surprisingly similar to the volume doubling times we reported for many of the cases we explored, despite the differences in our model and these experiments. The curve fitting by a double exponential suggests that there will be continuous exponential growth of bubble diameter. So although the physics and gas transport are different from what we studied, the indication of the studies are the same.
منابع مشابه
Numerical Analysis of Water and Air in Venturi Tube to Produce Micro-Bubbles
Two-phase flow regimes are affected by conduit position, alignment, geometry, flow direction, physical characteristics, and flow rate of each phase as well as the heat flux toward the boundaries. Due to the importance of two-phase flow, numerous regimes have been identified. The first step in studying micro-bubble formation inside a venturi tube is to recognize the type of flow regimes. In this...
متن کاملHeat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger
If an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. Air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. This mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. Howeve...
متن کاملExperimental investigation of bubble growth and detachment in stagnant liquid column using image – based analysis
An experimental study has been carried out to characterize bubble formation, growth, and detachment mechanisms in a stagnant liquid column. Both bubble frequency and bubble detachment size were measured in different gas flow rates, injector diameters and orientations, submergence height, and liquid properties. Experiments were performed for air injection flow rate ranges between 200 mlph and 12...
متن کاملExperimental study on bubble absorber with multiple tangential nozzles
Visualization study of bubble growth with multiple tangential nozzles is investigated in a bubble absorber. Bubble behavior is studied with different flowing condition like still, co-current and counter-current flow of water. Effect of air flow rate, water flow rate, nozzle diameters, number of nozzles and orientation of nozzle angle with reference to vertical plane on bubble diameter is studie...
متن کاملOptimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کامل