The effect of infusion rate and catheter length on the temperature of warming fluid

نویسندگان

  • Seong Ho Lee
  • Hae Kyu Kim
  • Sung Chun Park
  • Eun Soo Kim
  • Tae Kyun Kim
  • Chae Sun Kim
چکیده

BACKGROUND We used warming fluid for maintenance of body temperature in operating room or intensive care unit. This study was aimed to investigate the effect of infusion rate and catheter length on the temperature of warming fluid. METHODS Normal saline was used for testing infusion and temperature of infusion was maintained by a warmer as 40. The temperatures of solution in infusion line were measured at 0, 25, 50, 75, and 100 cm apart from warmer at six different flow rates (100, 200, 300, 700, 1,400, and 2,100 ml/h). We also measured the temperature changes at room temperature (RT) and 5, 10, and 15 above RT. RESULTS The time to maintain solution temperature as 40 was 165, 122, 37, 37, 21, and 19 s at flow rate 100, 200, 300, 700, 1,400, and 2,100 ml/h. The peak temperature was 43.58 +/- 0.58, 44.43 +/- 1.18, 44.37 +/- 0.70, 43.79 +/- 0.61, 42.82 +/- 0.97, and 42.11 +/- 0.92 according to increasing flow rate. The temperature at 100 cm apart from warmer was 23.96 +/- 1.53, 25.46 +/- 2.76, 29.32 +/- 3.47, 31.40 +/- 5.38, 31.39 +/- 6.75, and 38.14 +/- 0.96 according to increasing flow rate. CONCLUSIONS These results suggested that the decreasing rate of temperature was related inversely to the flow rate and directly to the catheter length. There may be needed a rapid infusion pump with adequate heating system at a high flow rate and to locate the warmer close to patient for reserving a heating effect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Foley Catheter in Prepration of Cervix for Delivery

Abstract The aim of this study was comparing the efficacy of induction of labor using balloon Foley catheter with conventional Oxytocin infusion method in cases of unfavorable cervix. 60 pregnant women that had an indication for induction of labor with a singleton vertex fetuses, intact membranes, and bishop score lower than 4 interred in this study and allocated in one of two induction method...

متن کامل

Comparison of the Effects of Intralipid 10% and 20% on Peripheral Catheter Ablation in a Pediatric Intensive Care Unit

Background: Energy deficit is a common and serious problem in pediatric intensive care units. Parenteral nutrition, either alone or in combination with enteral nutrition, can improve nutrient delivery in critically ill patients by preventing or correcting the energy deficit and improving the outcomes. Intralipid 10% and 20% are lipid emulsions, widely used in parenteral nutrition. Despite sever...

متن کامل

Effective methods of in-line intravenous fluid warming at low to moderate infusion rates.

Three methods of warming intravenous (IV) fluids were examined. An in-line blood warmer was generally ineffective at flow rates of < 250 mL/hr but did produce temperatures of 30 to 31 degrees C at the catheter when the infusion rate was 500 to 1,000 mL/hr and the tubing was insulated. An in-line hot water bath produced temperatures of > or = 30 degrees C at flow rates of 200 to 1,000 mL/hr with...

متن کامل

مقایسه میزان موفقیت فراکشنال اینداکشن همراه با تزریق اکستراآمنیوتیک نرمال‌سالین و کشش روی گردن رحم توسط سوند فولی برای ختم حاملگی‌های 3 ماهه دوم

The objective of the present study was to compare the success rate of extra-amniotic saline with traction on the cervix with folly catheter for termination of second trimester pregnancies. A randomized trial of extra-amniotic saline infusion versus traction on the cervix with folly catheter was performed on 200 patients with gestational age of 14-28 weeks who required induction of lab...

متن کامل

The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections

Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 58  شماره 

صفحات  -

تاریخ انتشار 2010