Pii: S1388-2457(02)00030-5

نویسندگان

  • Manfred Fuchs
  • Jörn Kastner
  • Michael Wagner
  • Susan Hawes
  • John S. Ebersole
چکیده

Objectives: We used a 3-compartment boundary element method (BEM) model from an averaged magnetic resonance image (MRI) data set (Montreal Neurological Institute) in order to provide simple access to realistically shaped volume conductor models for source reconstruction, as compared to individually derived models. The electrode positions were transformed into the model’s coordinate system, and the best fit dipole results were transformed back to the original coordinate system. The localization accuracy of the new approach was tested in a comparison with simulated data and with individual BEM models of epileptic spike data from several patients. Methods: The standard BEM model consisted of a total of 4770 nodes, which describe the smoothed cortical envelope, the outside of the skull, and the outside of the skin. The electrode positions were transformed to the model coordinate system by using 3–5 fiducials (nasion, left and right preauricular points, vertex, and inion). The transformation consisted of an averaged scaling factor and a rigid transformation (translation and rotation). The potential values at the transformed electrode positions were calculated by linear interpolation from the stored transfer matrix of the outer BEM compartment triangle net. After source reconstruction the best fit dipole results were transformed back into the original coordinate system by applying the inverse of the first transformation matrix. Results: Test-dipoles at random locations and with random orientations inside of a highly refined reference BEM model were used to simulate noise-free data. Source reconstruction results using a spherical and the standardized BEM volume conductor model were compared to the known dipole positions. Spherical head models resulted in mislocation errors at the base of the brain. The standardized BEM model was applied to averaged and unaveraged epileptic spike data from 7 patients. Source reconstruction results were compared to those achieved by 3 spherical shell models and individual BEM models derived from the individual MRI data sets. Similar errors to that evident with simulations were noted with spherical head models. Standardized and individualized BEM models were comparable. Conclusions: This new approach to head modeling performed significantly better than a simple spherical shell approximation, especially in basal brain areas, including the temporal lobe. By using a standardized head for the BEM setup, it offered an easier and faster access to realistically shaped volume conductor models as compared to deriving specific models from individual 3-dimensional MRI data. q 2002 Elsevier Science Ireland Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S1388-2457(02)00297-3

For algorithm developers, this review details recent approaches to the problem, compares the accuracy of various algorithms, identifies common testing issues and proposes some solutions. For the algorithm user, e.g. electroencephalograph (EEG) technician or neurologist, this review provides an estimate of algorithm accuracy and comparison to that of human experts. Manuscripts dated from 1975 ar...

متن کامل

Pii: S1388-2457(02)00267-5

Objective: To examine the effect of the active task involvement versus the passive knowledge of the structure of the stimulation on eventrelated potentials (ERPs) to violation in number sequences. This should contribute to future development of an ERP test for neurological patients. Methods: ERPs were recorded in subjects who listened to 4-item sequences of numbers incrementing by one. Half of ...

متن کامل

Pii: S1388-2457(02)00292-4

Objectives: The objective of this study is to test the hypothesis that the immature human brain exhibits slow electrical activity that is not detected by conventional (i.e. high-pass filtered) electroencephalography (EEG). Methods: Six healthy preterm infants (conceptional age 33–37 weeks) were recorded bedside with direct current (DC) EEG during sleep. Epochs with quiet sleep were selected to ...

متن کامل

Pii: S1388-2457(00)00527-7

Objective: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. Method: The proposed system is based on the extended International 10±20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. Results: The positioning and nomenclature of the electrode system is desc...

متن کامل

Pii: S1388-2457(02)00163-3

Objectives: This report provides a systematic longitudinal analysis of the EEG from infancy into early childhood. Particular emphasis is placed on the empirical confirmation of a 6–9 Hz alpha-range frequency band that has previously been used in the infant EEG literature. Methods: EEG data in 1-Hz bins from 3 to 12 Hz were analyzed from a longitudinal sample of 29 participants at 5, 10, 14, 24,...

متن کامل

Pii: S1388-2457(00)00560-5

Objective: An exploratory data analysis framework, based on minimal spanning tree, is proposed as a means to support the analysis of single trial (ST) electrophysiological signals. The core of this framework is the compact description of the input ST sample in a form of content-dependent ordered lists. Based on the established hierarchies, ef®cient ways to increase the SNR, extract prototypical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002