Reliability of IL Monarch ion-selective electrode module for sodium, potassium, and chloride measurements.
نویسندگان
چکیده
We evaluated the IL Monarch random-access centrifugal analyzer for measurement of Na+, K+, and Cl- by an indirect potentiometric method. For different concentrations of control material, the total precision (CV) ranged between 0.82% and 1.14% for the three electrolytes; linearity was acceptable within a range of 103 to 215 mmol/L for Na+, 1.6-15.25 mmol/L for K+, and 80-173 mmol/L for Cl-. Data correlated well with those by flame photometry for Na+ and K+ and with those by coulometry for Cl-, both for various biological materials--sera, urines, dialysis fluids--and commercial control materials from various producers. Stability of the potentiometric signal was acceptable: daily variations were 0.2 mV for Na+, 0.05 mV for K+, and 0.03 mV for Cl-. Accordingly, we conclude that the system supplies reproducible and accurate results while being easy to use and requiring little maintenance. The use of indirect potentiometry offers results consistent with those obtained with traditional methods, and easily interpretable by clinical staff. However, better information about the actual ion activity in the tested sample for certain pathologies such as hyperlipemia and dysproteinemia could be obtained by methods involving direct potentiometry.
منابع مشابه
Determination and Modeling of Activity Coefficients of Sodium Chloride in (Glycerol + Water) Mixtures Based on Potentiometric Measurements
In this work, the results concerning to the mean activity coefficient measurements for NaCl in the (glycerol + water) system using the potentiometric method are reported. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type: Ag|AgCl|NaCl (m), glycerol (wt%), H2O (1 - wt)%|Na-ISE, in various mixed solvent systems containing 0, 5, 10,...
متن کاملBenzalkonium interference with test methods for potassium and sodium.
Six automated instruments that measure sodium and potassium were tested for interference from two compounds used in catheters. Tridodecylmethylammonium heparin did not interfere with any of the methods. However, benzalkonium heparin falsely increased sodium measurement with the Kodak Ektachem, and falsely increased potassium measurements with three instruments (Beckman Astra, Baxter Paramax, an...
متن کاملEvaluation of the Jokoo-ION 150 AC: Guidelines for the evaluation of analysers by ion-selective electrodes
The Jokoo-ION 150 AC is an automatic sodium, potassium and chloride analyser which uses ion-selective electrodes.The sample mode can be whole-blood, serum or urine. To evaluate a urine sample, a previous dilution (1:6) with the standard 1 solution is required. For three concentrations of control materials, the total precision (CV) ranged from 0.17 to 1.22% for sodium, 0.22 to 1.69% for potassiu...
متن کاملThermodynamic Study of the Ternary Electrolyte (1-Butyl-3-methylimidazolium chloride + sodium chloride + Water) System Using Potentiometric Measurements
In this paper, the thermodynamic properties of the aqueous mixed electrolyte system containing 1-butyl-3-methylimidazolium chloride ([BMIm]Cl) and NaCl are reported based on the potentiometric method. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type:Ag-AgCl [BMIm]Cl (m1), NaCl(m2), H2O│IL-...
متن کاملIodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 34 4 شماره
صفحات -
تاریخ انتشار 1988