Quality Assurance / Phantoms

نویسنده

  • Ryan G Lafratta
چکیده

Gamma index pass rates were evaluated for an anthropomorphic phantom using both 2D and 3D calculations. The phantom was irradiated with the traditional dosimetry insert loaded with radiochromic film and TLD, and then with a 3D dosimetry insert. A comparison with the calculated dose distribution showed that both the PRESAGE® dosimeter and the film and TLD system agreed with the plan to within 5% using 2D gamma index criteria. The 3D gamma index showed a slightly higher pass rate than the 2D gamma index at 3%/3mm, and comparable pass rates using more generous constraints. The acceptable number of pixels passing the tighter constraints (3%/3mm) might be dependent upon the choice between a 2D calculation versus a 3D calculation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

Ultrasound Equipment Quality Assurance

Components of an Ultrasound Quality Assurance Program 257 Quality Assurance and Preventive Maintenance 257 Tissue-Mimicking Phantoms 257 Tissue Properties Represented in Phantoms 257 Typical Quality Assurance Phantom Design 257 Cautions About Phantom Desiccation 258 Basic Quality Control Tests 259 Visual Inspection 259 Transducer Choice 259 System Sensitivity 260 Photography and Gray-Scale Hard...

متن کامل

Quality Assurance, Accuracy, Precision and Phantoms

When an instrument such as an MRI scanner is installed and handed over to the user, a series of acceptance tests is often carried out by the customer (Och et al., 1992; McRobbie and Quest, 2002; Och et al., 1992). The vendor’s installation engineer will also have carried out extensive testing, according to the manufacturer’s protocols, using phantoms (test objects), to ensure the instrument is ...

متن کامل

A T1 and ECV phantom for global T1 mapping quality assurance: The T1 mapping and ECV standardisation in CMR (T1MES) program

Background Myocardial T1 and extracellular volume (ECV) estimates have applications in a range of myocardial diseases. Factors responsible for systematic inaccuracies in T1 mapping are beginning to be known but little is known about its delivery at ‘health-care system’ scale and there is no global quality assurance (QA) system. Agarose phantoms are common in MRI and nickel ions preferred for lo...

متن کامل

Quality assurance for grey-scale imaging.

In 1992, the American College of Radiology (ACR) recommended a specific phantom and image analysis procedure for (x-ray) mammography (American College of Radiology 1992). This event removed uncertainty in the USA regarding quality assurance (QA) in mammography. Although the phantom and analysis procedure are probably not ideal, existence of definitive recommendations has resulted in essentially...

متن کامل

Phantoms / QA A quality assurance method that utilizes 3 D dosimetry and facilitates clinical interpretation

A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation Oldham Mark; Thomas Andrew; O'Daniel Jennifer; Juang Titania; Ibbott Geoffrey; Adamovics John; Kirkpatrick John P International journal of radiation oncology, biology, physics (2012), 84(2), 540-6. PURPOSE: To demonstrate a new three-dimensional (3D) quality assurance (QA) method that provides comprehe...