INTRODUCTION In HIV-infected patients on combination antiretroviral therapy (cART), the detection of episomal HIV 2-LTR circles is a potential marker for ongoing viral replication. Quantification of 2-LTR circles is based on quantitative PCR or more recently on digital PCR assessment, but is hampered due to its low abundance. Sample pre-PCR processing is a critical step for 2-LTR circles quantification, which has not yet been sufficiently evaluated in patient derived samples. MATERIALS AND METHODS We compared two sample processing procedures to more accurately quantify 2-LTR circles using droplet digital PCR (ddPCR). Episomal HIV 2-LTR circles were either isolated by genomic DNA isolation or by a modified plasmid DNA isolation, to separate the small episomal circular DNA from chromosomal DNA. This was performed in a dilution series of HIV-infected cells and HIV-1 infected patient derived samples (n=59). Samples for the plasmid DNA isolation method were spiked with an internal control plasmid. RESULTS Genomic DNA isolation enables robust 2-LTR circles quantification. However, in the lower ranges of detection, PCR inhibition caused by high genomic DNA load substantially limits the amount of sample input and this impacts sensitivity and accuracy. Moreover, total genomic DNA isolation resulted in a lower recovery of 2-LTR templates per isolate, further reducing its sensitivity. The modified plasmid DNA isolation with a spiked reference for normalization was more accurate in these low ranges compared to genomic DNA isolation. A linear correlation of both methods was observed in the dilution series (R2=0.974) and in the patient derived samples with 2-LTR numbers above 10 copies per million peripheral blood mononuclear cells (PBMCs), (R2=0.671). Furthermore, Bland-Altman analysis revealed an average agreement between the methods within the 27 samples in which 2-LTR circles were detectable with both methods (bias: 0.3875±1.2657 log10). CONCLUSIONS 2-LTR circles quantification in HIV-infected patients proved to be more accurate with a modified plasmid DNA isolation procedure compared to total genomic DNA isolation. This method enables the processing of more blood cells, thus enhancing quantification accuracy and sensitivity. An improved quantification of 2-LTR circles will contribute to the better understanding of ongoing replication in the HIV reservoir of patients on cART.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly Precise Measurement of HIV DNA by Droplet Digital PCR

Deoxyribonucleic acid (DNA) of the human immunodeficiency virus (HIV) provides the most sensitive measurement of residual infection in patients on effective combination antiretroviral therapy (cART). Droplet digital PCR (ddPCR) has recently been shown to provide highly accurate quantification of DNA copy number, but its application to quantification of HIV DNA, or other equally rare targets, ha...

متن کامل

Low-level detection and quantitation of cellular HIV-1 DNA and 2-LTR circles using droplet digital PCR.

Droplet digital PCR (ddPCR) is an emerging nucleic acid detection method that provides absolute quantitations of target sequences without relying on the use of standard curves. The ability of ddPCR to detect and quantitate total HIV-1 DNA and 2-LTR circles from a panel of patients on and off antiviral therapy was evaluated compared to established real-time (RT)-PCR methods. To calculate the dyn...

متن کامل

Lack of evidence for prolonged double-long terminal repeat episomal HIV DNA stability in vivo.

To the Editor: Low-level HIV replication seems to persist during long-term effective highly active antiretroviral therapy (HAART). The sites of this replication are unclear, and the resulting viremia would be too low to detect with conventional procedures. It has been proposed that latently infected resting CD4 T cells release the virus on activation or that viral replication persists in anatom...

متن کامل

Development of real-time PCR for quantitation of simian immunodeficiency virus 2-LTR circles.

BACKGROUND Non-human primates infected with simian immunodeficiency virus (SIV) represent a robust model to evaluate pre-clinical efficacy of HIV-1 preventive strategies and to determine the size of reservoir. METHODS We developed a real-time qPCR assay to specifically quantify episomal 2-LTR circular DNA in peripheral blood mononuclear cells and brain tissues from SIV-infected macaques. RE...

متن کامل

Integrated HIV DNA accumulates prior to treatment while episomal HIV DNA records ongoing transmission afterwards.

OBJECTIVE We investigated the dynamics of HIV RNA and HIV DNA levels after the commencement of raltegravir-based antiretroviral therapy (ART) in primary (PHI) and chronically HIV-infected (CHI) individuals (the PINT study). DESIGN We recruited 8 PHI and 8 CHI ART-naive individuals who commenced a 1-year combination regimen of Truvada and the integrase inhibitor raltegravir. METHODS Nonlinea...

متن کامل