How rebreathing anaesthetic systems control PaCO2: studies with a mechanical and a mathematical model.
نویسندگان
چکیده
Results from a proposed equation for rebreathing systems, (formula: see text), were compared with results from a mechanical model "lung" ventilated either with a Bain Breathing Circuit, or a circle system (Eger-Ethans type A) without soda lime. When values for carbon dioxide excretion (VCO2), dead spacetidal volume ratio (VD/VT), minute volume ventilation (VE), and fresh gas flow (VF) were varied over a wide range, the model and the equation yielded identical values of PaCO2. When VCO2 = 2.25 ml/kg, VD/VT = 0.5, and VE = 140 ml/kg, then fresh gas flows (VF) with both the equation and the model produced values of PaCO2 which were very close to those found by Bain and Spoerel in anaesthetized, artificially ventilated humans. It is concluded that the equation is an accurate mathematical representation of how rebreathing anaesthetic systems control PaCO2. It is expected that the equation will be useful in the clinical application of rebreathing anaesthetic systems, allowing the selection of minute volumes and fresh gas flows which will yield predictable PaCO2 values.
منابع مشابه
Alveolar gas relationships during the use of semi-closed rebreathing anaesthetic systems.
A black box and a geometrical approach have been used to deduce the relationships between alveolar oxygen and carbon dioxide concentrations when rebreathing occurs during the use of semi-closed anaesthetic rebreathing systems.
متن کاملGaseous homeostasis and the circle system. Factors influencing anaesthetic gas exchange.
A mathematical model of a subject breathing from a circle system has been used to follow the course of anaesthetic uptake during the simulated administration of 60% nitrous oxide, 2% halothane and 2% methoxyflurane, under non-rebreathing conditions and with fresh gas flows to the circle system of between 8 and 0.25 litre min-1. Compared with the non-rebreathing state, the use of a circle system...
متن کاملA Linear Approach to the Control of Vortex Induced Vibrations of Circular Cylinders with a 2-D Van der Pol Model for Structural Oscillator
In the present paper, a new 2-D Van der Polstructural oscillator model is introduced for the vortex induced vibrations of circular cylinders.The main purpose of this task is to control the recently introduced model by means of modern control definitions in state space. In order to control the system, the whole model is linearized about its equilibrium point by deriving state-space matrices. The...
متن کاملA review on West African Ebola epidemic dynamics models
Background and aims: The world is threatened by disease outbreak that reaches a public health emergency of international concern, studies to inform public and agencies for effective containment strategy are necessary. Several studies provided vital information of the dynamics and control of Ebola epidemic outbreak in West Africa. Methodologies and techniques in those researches...
متن کامل'Closed circuit' anaesthesia.
Aa inhalation anaesthetic is like a concerto-conducted in three movements, if one ignores the surgical cadenzas. The three movements of the well-conducted anaesthetic are: The induction, during which the patient is introduced to and thereafter loaded with an anaesthetic drug to produce a general tissue concentration sufficient for anaesthesia. The brain, with its rich blood supply, leads the ti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Canadian Anaesthetists' Society journal
دوره 25 2 شماره
صفحات -
تاریخ انتشار 1978