The psychometric function and reaction times of automated perimetry in normal and abnormal areas of the visual field in patients with glaucoma.
نویسندگان
چکیده
PURPOSE To study the relationship of reaction time to the psychometric function in normal subjects, normal sensitivity test locations in patients with glaucoma, and test locations with 10 to 20 dB loss in patients with glaucoma. METHODS The authors tested 10 patients with glaucoma and 10 age-matched normal volunteers with the Humphrey perimeter, first with program 24-2 and then with the method of constant stimuli to generate frequency of seeing curves. At two widely separated visual field locations on the program 24-2 grid, they presented stimuli in 2-dB intervals, 10 dB either side of the program 24-2 threshold, at 0 dB and 60 dB (15 repetitions per intensity). For the patients with glaucoma, they chose a visual field location with normal sensitivity and a location in an area of 10 to 20 dB loss. RESULTS Analysis of variance with post hoc t-tests showed that reaction time (RT) at the 0-dB intensity was prolonged by approximately 90 msec in the abnormal sensitivity test location of patients with glaucoma compared to the control and the glaucoma normal sensitivity groups (P<0.0001). However, this difference was accounted for by only 4 of the 10 patients with glaucoma, reaching 100% of stimuli seen with the brightest stimulus at the moderately damaged test location. Reaction time at the frequency of seeing 50% estimated threshold showed no significant differences among the groups. Prolongation of RT from the 0-dB value was analyzed as a function of increasing attenuation of stimulus intensity. The results fit the equation RT = a + b(Intensity3) for all groups. CONCLUSIONS There is no significant difference in RT between normal subjects and patients with glaucoma either at threshold or to suprathreshold stimuli. Reaction time increases after a power function with increasing attenuation of stimulus intensity up to the threshold.
منابع مشابه
Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کاملDepression and Quality of Life in Patients with Glaucoma
Purpose: To investigate the frequency of depression and quality of life in patients with glaucoma. Methods: This cross-sectional study included 204 patients (102 males and 102 females) with a mean age of 58.9±11.96 and a range of 40 to 85 years old. Achromatic perimetry was performed, using the HFA SITA-standard 24-2. Severity was stratified according to the Nelson Glaucoma Severity Scale (base...
متن کاملDetecting visual function abnormalities using the Swedish interactive threshold algorithm and matrix perimetry in eyes with glaucomatous appearance of the optic disc.
OBJECTIVE To compare the ability of 24-2 frequency-doubling perimetry (FDP-Matrix) with standard automated perimetry with the Swedish interactive threshold algorithm (SAP-SITA) in detection of visual function abnormalities in patients with glaucomatous-appearing optic discs (GAOD). METHODS This observational case-control study included 80 patients with GAOD and 54 control subjects diagnosed b...
متن کاملMotion automated perimetry identifies early glaucomatous field defects.
OBJECTIVE To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n...
متن کاملDetection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry.
OBJECTIVE To investigate whether frequency-doubling perimetry (FDP) predicts future visual field loss with achromatic automated perimetry (AAP), just as it may be predicted with short-wavelength automated perimetry (SWAP). METHODS We recruited 62 patients selectively from an urban glaucoma practice. At the commencement of the study, each patient had ocular hypertension with normal visual fiel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 37 5 شماره
صفحات -
تاریخ انتشار 1996