High-frequency percussive ventilation and low tidal volume ventilation in burns: a randomized controlled trial.

نویسندگان

  • Kevin K Chung
  • Steven E Wolf
  • Evan M Renz
  • Patrick F Allan
  • James K Aden
  • Gerald A Merrill
  • Mehdi C Shelhamer
  • Booker T King
  • Christopher E White
  • David G Bell
  • Martin G Schwacha
  • Sandra M Wanek
  • Charles E Wade
  • John B Holcomb
  • Lorne H Blackbourne
  • Leopoldo C Cancio
چکیده

OBJECTIVES In select burn intensive care units, high-frequency percussive ventilation is preferentially used to provide mechanical ventilation in support of patients with acute lung injury, acute respiratory distress syndrome, and inhalation injury. However, we found an absence of prospective studies comparing high-frequency percussive ventilation with contemporary low-tidal volume ventilation strategies. The purpose of this study was to prospectively compare the two ventilator modalities in a burn intensive care unit setting. DESIGN Single-center, prospective, randomized, controlled clinical trial, comparing high-frequency percussive ventilation with low-tidal volume ventilation in patients admitted to our burn intensive care unit with respiratory failure. SETTING A 16-bed burn intensive care unit at a tertiary military teaching hospital. PATIENTS Adult patients ≥ 18 yrs of age requiring prolonged (> 24 hrs) mechanical ventilation were admitted to the burn intensive care unit. The study was conducted over a 3-yr period between April 2006 and May 2009. This trial was registered with ClinicalTrials.gov as NCT00351741. INTERVENTIONS Subjects were randomly assigned to receive mechanical ventilation through a high-frequency percussive ventilation-based strategy (n = 31) or a low-tidal volume ventilation-based strategy (n = 31). MEASUREMENTS AND MAIN RESULTS At baseline, both the high-frequency percussive ventilation group and the low-tidal volume ventilation group had similar demographics to include median age (interquartile range) (28 yrs [23-45] vs. 33 yrs [24-46], p = nonsignificant), percentage of total body surface area burn (34 [20-52] vs. 34 [23-50], p = nonsignificant), and clinical diagnosis of inhalation injury (39% vs. 35%, p = nonsignificant). The primary outcome was ventilator-free days in the first 28 days after randomization. Intent-to-treat analysis revealed no significant difference between the high-frequency percussive ventilation and the low-tidal volume ventilation groups in mean (± sd) ventilator-free days (12 ± 9 vs. 11 ± 9, p = nonsignificant). No significant difference was detected between groups for any of the secondary outcome measures to include mortality except the need for "rescue" mode application (p = .02). Nine (29%) in the low-tidal volume ventilation arm did not meet predetermined oxygenation or ventilation goals and required transition to a rescue mode. By contrast, two in the high-frequency percussive ventilation arm (6%) required rescue. CONCLUSIONS A high-frequency percussive ventilation-based strategy resulted in similar clinical outcomes when compared with a low-tidal volume ventilation-based strategy in burn patients with respiratory failure. However, the low-tidal volume ventilation strategy failed to achieve ventilation and oxygenation goals in a higher percentage necessitating rescue ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-frequency percussive ventilation for severe inhalation injury.

998 April 2014 A HEALTHY 26-yr-old with singed nares, carbonaceous tracheal secretions, and respiratory distress was intubated following a house fire. Bronchoscopy (fig.) revealed soot throughout the tracheobronchial tree consistent with severe inhalational injury. Despite ARDSNet goal-directed conventional mechanical ventilation, adequate muscle relaxation, and aerosolized pharmacotherapy of a...

متن کامل

PReVENT - protective ventilation in patients without ARDS at start of ventilation: study protocol for a randomized controlled trial

BACKGROUND It is uncertain whether lung-protective mechanical ventilation using low tidal volumes should be used in all critically ill patients, irrespective of the presence of the acute respiratory distress syndrome (ARDS). A low tidal volume strategy includes use of higher respiratory rates, which could be associated with increased sedation needs, a higher incidence of delirium, and an increa...

متن کامل

Volume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial

Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...

متن کامل

High-frequency percussive ventilation: pneumotachograph validation and tidal volume analysis.

INTRODUCTION High-frequency percussive ventilation (HFPV) is an increasingly used mode of mechanical ventilation, for which there is no proven real-time means of measuring delivered tidal volume (V(T)). OBJECTIVE To validate a pneumotachograph for HFPV and then exploit flow-sensor data to describe the behavior of both low-frequency and high-frequency breaths. METHODS Sensor performance was ...

متن کامل

Measurement of pulsatile tidal volume, pressure amplitude, and gas flow during high-frequency percussive ventilation, with and without partial cuff deflation.

OBJECTIVE With a high-frequency percussive ventilator and a mechanical lung model, to measure tidal volume (V(T)), pulsatile pressure amplitude (difference between peak and nadir pulsatile pressure [DeltaP];), and mean airway pressure (P (aw)) at various pulsatile frequencies, pulsatile inspiratory-expiratory ratios (I:E(p)), and pressures (measured at the interface between the pulse-generator ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 38 10  شماره 

صفحات  -

تاریخ انتشار 2010