Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens

نویسندگان

  • David Klonoff
  • Irina Nayberg
  • Marissa Thonius
  • Florian See
  • Mona Abdel-Tawab
  • Frank Erbstein
  • Thomas Haak
چکیده

BACKGROUND To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR(®), FlexPen(®), and KwikPen™. METHODS For the accuracy assessment, 60 of each of the 3 tested devices were used for the delivery of 3 different doses (1 U, half-maximal dose, and maximal dose), which were measured gravimetrically. For the injection force assessment, 20 pens of each of the 3 types were tested twice at half-maximal and once at maximal dose, at an injection speed of 6 U/s. RESULTS All tested pens met the International Organization for Standardization (ISO) requirements for dosing accuracy, with Gla-300 SoloSTAR showing the lowest between-dose variation (greatest reproducibility) at all dose levels. Mean injection force was significantly lower for Gla-300 SoloSTAR than for the other 2 pens at both half maximal and maximal doses (P < .0271). CONCLUSION All tested pens were accurate according to ISO criteria, and the Gla-300 SoloSTAR pen displayed the greatest reproducibility and lowest injection force of any of the 3 tested devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Usability of the Gla-300 Injection Device Compared With Three Other Commercialized Disposable Insulin Pens

New insulin glargine 300 U/mL (Gla-300; Toujeo ®), recently approved for use in the United States and in Europe, has more stable and prolonged pharmacokinetic and pharmaco-dynamic profiles compared with glargine 100 U/mL (Gla-100; Lantus ®). 1 In clinical practice this translates into a comparable glucose-lowering effect and reduced risk of hypoglycemia. 2–4 To deliver Gla-300, the well-known a...

متن کامل

Injection force of SoloSTAR® compared with other disposable insulin pen devices at constant volume flow rates.

BACKGROUND Injection force is a particularly important practical aspect of therapy for patients with diabetes, especially those who have dexterity problems. This laboratory-based study compared the injection force of the SoloSTAR® insulin pen (SoloSTAR; sanofi-aventis) versus other available disposable pens at injection speeds based on the delivered volume of insulin released at the needle. M...

متن کامل

Dose accuracy and injection force of disposable pens delivering pramlintide for the treatment of diabetes.

BACKGROUND The pen injection format, typically used for insulin administration, has been adapted for the injectable, noninsulin diabetes therapy pramlintide. Administered before major meals, pramlintide therapy requires two to four injections/day in addition to the patients' usual insulin injections. The dose accuracy and injection force was determined for the 60 and 120 µg pramlintide pens. ...

متن کامل

Dose accuracy and injection force of different insulin glargine pens.

BACKGROUND Dose accuracy and injection force, representing key parameters of insulin pens, were determined for three pens delivering insulin glargine-based copies, Pen Royale (WR) and DispoPen (WD) for Glaritus® (Wockhardt) and GanLee Pen (GL) for Basalin® (Gan & Lee), compared with pens of the originator, ClikSTAR® (CS) and SoloSTAR® (SS) for Lantus® (Sanofi). METHODS Using the weighing proc...

متن کامل

Dosing accuracy and insulin flow rate characteristics of a new disposable insulin pen, FlexTouch, compared with SoloSTAR.

BACKGROUND The introduction of the FlexTouch® (FT; Novo Nordisk; insulin aspart), a prefilled insulin pen with a spring-loaded mechanism, has created more insulin pen options. The present study compared the dosing accuracy of the FT with that of the manually operated SoloSTAR® (SS; Sanofi; insulin glulisine). The volumetric flow rate of insulin delivery with the FT was also evaluated. METHODS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015