Implantable defibrillator lead extraction with optimized standard extraction techniques

نویسندگان

  • Xian-Ming Chu
  • Xue-Bin Li
  • Ping Zhang
  • Yi An
  • Jiang-Bo Duan
  • Long Wang
  • Ding Li
  • Bing Li
  • Ji-Hong Guo
چکیده

BACKGROUND Implantable cardioverter-defibrillator (ICD) leads might not be extracted especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate transvenous extraction of ICD leads using optimized standard techniques. METHODS We prospectively analyzed clinical characteristics, optimized extraction techniques and the feasibility of extraction for 40 patients (33 males; mean age 47.9 ± 16.1 years) with 42 ICD leads. RESULTS Complete procedural success rate was 95.2% (40/42), and the clinical success rate was 97.6% (41/42). One ICD lead required cardiothoracic surgery. Minor complications occurred in three cases (7.5%), and no major complications or death occurred. Locking stylets were used to extract most leads (34, 81.0%) and almost half of the leads (20, 47.6%) required mechanical dilatation to free fibrotic adhesions; these leads had been implanted for a longer period of time than the others (43.7 ± 18.2 vs. 18.4 ± 13.4 months, P < 0.05). Three-quarters of the leads (30, 71.4%) were extracted with locking stylets plus manual traction (12, 28.6%), or mechanical dilatation with counter-traction (18, 42.8%) by the superior vena cava approach and one-quarter of the leads (11, 26.2%) were removed by optimized snare techniques using the femoral vein approach. Median extraction time was 20 min (range 2-68 min) per lead. Linear regression analysis showed that the extraction time was significantly correlated with implant duration (r = 0.70, P < 0.001). Median follow-up was 14.5 months (range 1-58 months), no infection, or procedure-related death occurred in our series. CONCLUSIONS Our optimized procedure for transvenous extraction of ICD leads provides a practical and low-cost method for standard procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques

BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical exp...

متن کامل

Delayed Perforation of the Right Ventricular Wall by a Single Standard-Caliber Implantable Cardioverter-Defibrillator Lead Detected by Multidetector Computed Tomography

We present an unusual case of a delayed right ventricular perforation by a single standard-caliber implantable cardioverter-defibrillator lead, which manifested 14 days after implantation. Multidetector computed tomography could clearly display the lead perforation, and allow for identification of the associated sequelae such as pericardial effusion and planning the lead extraction strategy.

متن کامل

Successful extraction of an implantable cardioverter-defibrillator lead in a patient with pocket infection via the femoral approach with a basket snare

A 27-year-old man was admitted to our institution with implantable cardioverter-defibrillator (ICD) pocket infection. The ICD (single chamber, dual shock coils) was implanted for the prevention of aborted sudden cardiac death due to idiopathic ventricular fibrillation. Because we could not use locking stylet and countertraction manuever, baseket snare with metal wire should be hanged at the max...

متن کامل

Prophylactic lead extraction at implantable cardioverter-defibrillator generator change.

BACKGROUND Current implantable cardiac devices have a finite battery life of ≈3 to 7 years for implantable cardioverter-defibrillators. It is current practice to reuse all properly functioning intravascular leads. We tested the hypothesis that a strategy of prophylactic lead removal at the time of device change would be superior under some conditions to the current practice of lead reuse. MET...

متن کامل

Malfunction of endocardial defibrillator leads and lead extraction: where do they meet?

AIMS The development of new extraction techniques has improved the success rate of intravascular extraction of pacemaker and defibrillator leads, and hence the practice of extraction is expanding. However, the indications for lead extraction of malfunctioning leads in patients with an implantable cardioverter defibrillator (ICD) are still not well established. METHODS AND RESULTS We reviewed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2013