Correction of residual hyperopia after cataract surgery using the light adjustable intraocular lens technology.

نویسندگان

  • Arturo Chayet
  • Christian A Sandstedt
  • Shiao H Chang
  • Paul Rhee
  • Barbara Tsuchiyama
  • Daniel Schwartz
چکیده

PURPOSE To determine whether residual hyperopia could be corrected postoperatively using the light adjustable lens technology in patients undergoing cataract surgery and light adjustable lens implantation. DESIGN Prospective, nonrandomized clinical trial. METHODS Fourteen eyes of 14 patients were studied. The manifest refraction, uncorrected visual acuity (UCVA), and best-corrected visual acuity (BCVA) were determined with follow-up time to determine the achieved refractive corrections and their stability. RESULTS Of 14 eyes, 13 eyes (92.9%) achieved +/- 0.25 diopters (D) of the target refraction at one day post lock-in, with 100% of the eyes achieving the targeted refractive adjustment within 0.5 D or better up to six months postoperative follow-up. All eyes treated show no change in manifest spherical refraction >0.25 D between one day post lock-in, and three and six months postoperative visits. The data demonstrate the stability of the achieved refractive change after the adjustment and lock-in procedures. The mean rate of change was 0.006 D per month, which is six times more stable than that of refractive procedures. CONCLUSIONS Residual hyperopia errors in the range of +0.25 to +2.0 D were successfully corrected with precision and significant improvement in UCVA and without compromising BCVA using the light adjustable intraocular lens technology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Managing residual refractive error after cataract surgery.

We present a review of keratorefractive and intraocular approaches to managing residual astigmatic and spherical refractive error after cataract surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), arcuate keratotomy, intraocular lens (IOL) exchange, piggyback IOLs, and light-adjustable IOLs. Currently available literature suggests that laser vision correc...

متن کامل

Artisan iris-fixated toric phakic and aphakic intraocular lens implantation for the correction of astigmatic refractive error after radial keratotomy.

We report 2 patients who had radial keratotomy (RK) to correct myopia. The first patient developed a postoperative hyperopic shift and cataract. Nine years post RK, she had intracapsular cataract extraction and implantation of an Artisan aphakic intraocular lens (IOL). Twenty years post RK, hyperopia and astigmatism progressed to +7.0 -5.75 x 100 with a best corrected visual acuity (BCVA) of 20...

متن کامل

Light-adjustable lens.

PURPOSE First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cyt...

متن کامل

The adjustable refractive surgery concept (ARS)

The primary goal of refractive surgery is the smallest residual refractive error and preserved contrast sensitivity with the same visual capacity under bright and dim illumination. Corneal refractive surgery cannot correct very high ametopias; from -10 to -14 D is the limit of myopia correction in the cornea and from +4 to +6 D, the limit of hyperopia correction. Intraocular refractive surgery ...

متن کامل

Light-adjustable intraocular lens in post-LASIK and post-traumatic cataract patient.

The case illustrates the use of a light-adjustable intraocular lens (IOL) in a patient who had had refractive surgery and developed blunt trauma with resultant flap damage and traumatic cataract. Consistent with early reports of the light adjustable IOL, which show positive results in non-LASIK eyes, this case suggests that the light-adjustable IOL may have similar benefits in the post-LASIK ey...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 147 3  شماره 

صفحات  -

تاریخ انتشار 2009