Electronic power transformers (EPTs) have been identified as emerging intelligent electronic devices in the future smart grid, e.g., the Energy Internet, especially in the application of renewable energy conversion and management. Considering that the EPT is directly connected to the medium-voltage grid, e.g., a10 kV distribution system, and its cascaded H-bridges structure, the common mode voltage (CMV) issue will be more complex and severe. The CMV will threaten the insulation of the entire EPT device and even produce common mode current. This paper investigates the generated mechanism and characteristics of the CMV in a cascaded H-bridge EPT (CHB-EPT) under both balanced and fault grid conditions. First, the CHB-EPT system is introduced. Then, a three-phase simplified circuit model of the high-voltage side of the EPT system is presented. Combined with a unipolar modulation strategy and carrier phase shifting technology by rigorous mathematical analysis and derivation, the EPT internal CMV and its characteristics are obtained. Moreover, the influence of the sinusoidal pulse width modulation dead time is considered and discussed based on analytical calculation. Finally, the simulation results are provided to verify the validity of the aforementioned model and the analysis results. The proposed theoretical analysis method is also suitable for other similar cascaded converters and can provide a useful theoretical guide for structural design and power density optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation

In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...

متن کامل

Conduction and Dead-Time Voltage Drops Estimation of Asymmetric Cascaded H-Bridge Converters Utilizing Level-Shifted PWM Scheme

Linear AC power supplies can be replaced by their nonlinear switching counterparts due to the lower voltage drops and higher efficiency and power density of switching-mode inverters. Multilevel cascaded H-bridge (CHB) converters are the preferred inverter structure because of modular configuration, control, and protection. The output voltage quality in CHB converters depends on the number of ou...

متن کامل

Design and Simulation of a 100 kVA Intelligent Universal Transformer Enjoying the Voltage Ratio of 20kv:380v

In order to reduce the volume and size of distribution power transformer, precise and extended controlling of transformer output, the conventional transformers are replaced by intelligent universal transformers (IUTs). In this paper, an IUT, typical of Iran national grid, with the voltage ratio of 20kV:380 V is designed and simulated. Regarding the IUT implementation, a cascaded H-bridge invert...

متن کامل

Reduction the Number of Power Electronic Devices of a Cascaded Multilevel Inverter Based on New General Topology

In this paper, a new cascaded multilevel inverter by capability of increasing the number of output voltage levels with reduced number of power switches is proposed. The proposed topology consists of series connection of a number of proposed basic multilevel units. In order to generate all voltage levels at the output, five different algorithms are proposed to determine the magnitude of DC volta...

متن کامل

استفاده از اینورتر چندسطحی با کنترل‌کننده غیرخطی مستقیم برای اتصال مزرعه خورشیدی به شبکه

The solar photovoltaic (PV) farm delivers its harvested DC energy to the AC grid via power electronic interfaces. With insolation as well as ambient temperature variations, these power electronic converters should regulate operating point at optimal point to extracting maximum power from PV cells. In this paper, a direct nonlinear control method is developed for cascaded H-bridge multilevel inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017