Microsection analysis of cortical form-fit of a custom femoral component in total hip arthroplasty: an in vitro study

نویسندگان

  • Ulf Gunther Leichtle
  • Carmen Ina Leichtle
  • Franz Martini
چکیده

Custom femoral components have been developed for total hip arthroplasty to maximize cortical form-fit and thereby to reduce the problems of stress shielding and aseptic loosening. Limited information is available about how much endosteal cortical contact can actually be achieved with these expensive implants. The aim of this study was therefore to verify the exact cortical contact of a custom made stem using microsections and comparing it to a standard stem with similar design. In 8 human femurs (3 matched pairs and 2 separate specimens), custom femoral prostheses (Adaptiva; 5 femurs: 3 matched and 2 separate) and conventional femoral prostheses (Alloclassic; 3 matched femurs) were implanted. Endosteal cortical contact was determined from CAD planning drafts and microsections cut from the specimens with a diamond saw. Microsection analysis of the paired femurs showed that contact between prosthesis and bone varied clearly along the length of the femoral stem. Total cortical contact was considerably greater in custom prostheses than conventional prostheses (custom, 47%; conventional, 32%), but markedly less than the total contact predicted by the manufacturer (84% to 90%). The custom prosthesis had more lateral cortical contact on CAD planning drafts (cortical contact: medial, 60%; lateral, 53%) than on specimen microsections after implantation (medial, 64%; lateral, 24%).In summary, the philosophy of anchorage of both prostheses types could be confirmed. However, areas of cortical contact of the custom made prosthesis were considerably smaller compared to the pre-operative planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

A Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?

Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012