The impossibility of affine reconstruction from perspective image pairs obtained by a translating camera with varying parameters
نویسندگان
چکیده
Contrary to the claim in the literature that the affine reconstruction is possible from two images captured by a translating camera with unknown and varying parameters, we show that such a reconstruction is in fact impossible. In other words, the knowledge that “ the camera’s motion between the two images is just a pure translation” is an insufficient piece of information for affine reconstruction.
منابع مشابه
Self-calibration of Varying Internal Camera Parameters Algorithm Based on Quasi-affine Reconstruction
This paper presents an method of self-calibration of varying internal camera parameters that based on quasi-affine reconstruction. In a stratified approach to self-calibration, a projective reconstruction is obtained first and this is successively refined first to an affine and then to a Euclidean reconstruction. It has been observed that the difficult step is to obtain the affine reconstructio...
متن کاملAffine Structure from Translational Motion in Image Sequences
In this paper a method for obtaining affine structure from an image sequence taken by a translating camera with constant intrinsic parameters is presented. A general geometric constraint, expressed using the camera matrices, is derived and this constraint is used in a least squares solution of the problem. The first step is to obtain a projective reconstruction, in the form of a sequence of cam...
متن کاملUncalibrated active affine reconstruction closing the loop by visual servoing
This paper presents a new approach to active affine reconstruction without an exact knowledge of the robot’s kinematic model nor camera intrinsic parameters. Affine reconstruction from perspective image pairs is easy if the motion of the camera between the two images is a pure translation. If the robot is not well calibrated, a pure translation achieved with an open loop control would lead to a...
متن کاملEuclidean Structure from Uncalibrated Images
A number of recent papers have demonstrated that camera "selfcalibration" can be accomplished purely from image measurements, without requiring special calibration objects or known camera motion. We describe a method, based on self-calibration, for obtaining (scaled) Euclidean structure from multiple uncalibrated perspective images using only point matches between views. The method is in two st...
متن کاملEvaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators
Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pattern Recognition Letters
دوره 24 شماره
صفحات -
تاریخ انتشار 2003