Capsule Contraction Syndrome with a Microincision Foldable Hydrophilic Acrylic Intraocular Lens: Two Case Reports and Review of the Literature
نویسندگان
چکیده
Here we present 2 cases of capsule contraction syndrome (CCS). In both cases, a hydrophilic acrylic Akreos MI60 (Bausch and Lomb) intraocular lens (IOL) was implanted in the capsular bag through microincision cataract surgery, and the literature on the subject is reviewed. Since CCS has been described after the implantation of every IOL type, it is unlikely that the Akreos MI60 chemical and physical properties may cause CCS. When CCS occurs with IOLs composed of increasingly flexible materials that are inserted through incisions of decreasing size, a severe dislocation and deformation of IOL optics and haptics may develop. In both cases illustrated here, Nd:YAG laser anterior capsulotomy was highly effective. Hence, also based on the literature, which reports severe complications as a result of surgical intervention, it is suggested that Nd:YAG laser anterior capsulotomy be the first line of CCS treatment when the luxation of an IOL capsular bag is absent.
منابع مشابه
Late Opacification of Foldable Intraocular Lenses
Objective: To report opacification of hydrophilic acrylic and silicone foldable intraocular lenses (IOL). Designs: Case series. Participants: Five patients with IOL opacification. Results: We report five eyes of five patients with late opacification of the intraocular lens (IOL). Three patients had hydrophilic acrylic (SC60B-OUV-MDR, Inc), two had silicone IOL (Allergan SI30NB). Two out of the ...
متن کاملAdhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study.
AIMS To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between th...
متن کاملComparison of sulcus implantation of single-piece hydrophilic foldable acrylic and polymethylmethacrylate intraocular lenses in eyes with posterior capsule tear during phacoemulsification surgery.
PURPOSE To compare the results of sulcus implantation of acrylic and poly(methylmethacrylate) (PMMA) intraocular lens (IOL) in eyes with posterior capsule tear during phacoemulsification surgery. METHODS In all eyes a posterior capsule tear developed during phacoemulsification surgery and an IOL to the ciliary sulcus was implanted primarily. A total of 89 eyes of 88 patients received hydrophi...
متن کاملComparison of clinical results between heparin surface modified hydrophilic acrylic and hydrophobic acrylic intraocular lens.
PURPOSE To compare the clinical results of heparin surface modified (HSM) hydrophilic acrylic intraocular lens (IOL) with those of hydrophobic acrylic IOL. METHODS One hundred patients with cataract were randomized to receive one of acrylic foldable IOLs after phacoemulsification: HSM hydrophilic acrylic IOL (n=50) BioVue3 (BioVue, OII, Ontario, CA, USA) and hydrophobic acrylic IOL (n=50) Sen...
متن کاملA prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.
AIMS To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). METHODS 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior cap...
متن کامل