Inception and propagation of positive streamers in high-purity nitrogen: effects of the voltage rise-rate
نویسندگان
چکیده
Controlling streamer morphology is important for numerous applications. Up to now, the effect of the voltage rise rate was only studied across a wide range. Here we show that even slight variations in the voltage rise can have significant effects. We have studied positive streamer discharges in a 16 cm point-plane gap in high-purity nitrogen 6.0, created by 25 kV pulses with a duration of 130 ns. The voltage rise varies by a rise rate from 1.9 to 2.7 kV ns−1 and by the first peak voltage of 22 to 28 kV. A structural link is found between smaller discharges with a larger inception cloud caused by a faster rising voltage. This relation is explained by the greater stability of the inception cloud due to a faster voltage rise, causing a delay in the destabilization. Time-resolved measurements show that the inception cloud propagates slower than an earlier destabilized, more filamentary discharge. This explains that the discharge with a faster rising voltage pulse ends up being shorter. Furthermore, the effect of remaining background ionization in a pulse sequence has been studied, showing that channel thickness and branching rate are locally affected, depending on the covered volume of the previous discharge. (Some figures may appear in colour only in the online journal)
منابع مشابه
Positive streamers in air and nitrogen of varying density: experiments on similarity laws
Positive streamers in ambient air at pressures from 0.013 to 1 bar are investigated experimentally. The voltage applied to the anode needle ranges from 5 to 45 kV, the discharge gap from 1 to 16 cm. Using a ”slow” voltage rise time of 100 to 180 ns, the streamers are intentionally kept thin. For each pressure p, we find a minimal diameter dmin. To test whether streamers at different pressures a...
متن کاملOn the inception of streamers from sprite halo events produced by lightning discharges with positive and negative polarity
[1] In the sprite halo events produced by cloud‐to‐ground lightning discharges, the spatial offsets, long delays, and polarity asymmetry related to the inception of sprite streamers are yet to be explained consistently with observations. In the present work, we use a two‐dimensional model and a high‐resolution one‐dimensional plasma fluid model accounting for electron impact ionization, dissoci...
متن کاملPositive and negative streamers in ambient air: measurements
Positive and negative streamers are studied in ambient air at 1 bar; they emerge from a needle electrode placed 40 mm above a planar electrode. The amplitudes of the applied voltage pulses range from 5 to 96 kV; most pulses have rise times of 30 ns or shorter. Diameters, velocities and energies of the streamers are measured. Two regimes are identified; a low voltage regime where only positive s...
متن کاملDetermination of Electric Field at Inception Based upon Current-Voltage Characteristics of AC Corona in Rod-Plane Gaps
This paper deals with the measurement of AC corona inception voltage, Vincp, at the tip of a rod electrode using a hemispherically-capped rod-plane electrode configuration for various rod radii with a short air gap. Effects of atmospheric pressure and temperature variation on Vincp are investigated experimentally. An empirical equation for the field form factors of the hemispherically cappe...
متن کاملInvestigation of positive streamers by double-pulse experiments, effects of repetition rate and gas mixture
Streamer discharges are often operated in a repetitively pulsed mode and are therefore influenced by species left over from the previous discharge, especially free electrons and ions. We have investigated these effects by applying two consecutive positive high voltage pulses of 200–700 ns duration to a point-plane gap in artificial air, pure nitrogen, other nitrogen–oxygen mixtures and pure arg...
متن کامل