Qualitative and Quantitative Contrast Enhanced Ultrasonography of the Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal Dogs

نویسندگان

  • Sue Yee LIM
  • Kensuke NAKAMURA
  • Keitaro MORISHITA
  • Noboru SASAKI
  • Masahiro MURAKAMI
  • Tatsuyuki OSUGA
  • Hiroshi OHTA
  • Masahiro YAMASAKI
  • Mitsuyoshi TAKIGUCHI
چکیده

Quantitative contrast enhanced ultrasound is a major breakthrough for ultrasound imaging in recent years. However, contrast enhancement of the pancreas is brief with bolus injection. To assess if continuous infusion of Sonazoid(®) can prolong the duration of pancreatic enhancement over bolus injections, eight adult dogs received bolus injection and continuous infusion of Sonazoid(®) on separate days. Contrast enhanced ultrasound of the pancreatic parenchyma and proximal descending duodenum was performed, and time intensity curves reflecting tissue perfusions were generated. Perfusion parameters- time to initial upslope, peak time, time to wash-out and peak intensity were calculated and evaluated. Fast wash-in to intense peak, followed by rapid wash-out was observed for time intensity curves of bolus injection. With continuous infusion, contrast wash-in to peak intensity was gradual, followed by long plateau and slow wash-out. Median contrast enhancement durations of the pancreas and duodenum were significantly prolonged by continuous infusion from 11 sec (range, 10 to 23 sec) and 16 sec (range, 3 to 43 sec) at bolus injection to 205 sec (range, 170 to 264 sec, P<0.01) and 193 sec (range, 169 to 216 sec, P<0.05), respectively. Median peak intensity of the pancreas was 100.9 MPV (range, 80.2 to 124.3 MPV) at bolus injection and 77.6 MPV (range, 58.2 to 99.5 MPV, P<0.05) at continuous infusion. Prolonged continuous imaging is afforded by continuous infusion of contrast agent. Peak intensity of the pancreas was slightly diminished in continuous infusion, but offered adequate imaging subjectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?

OBJECTIVES This study sought to determine the basis of detection of stenosis by myocardial contrast echocardiography using venous administration of microbubbles and to define the relative merits of bolus injection versus continuous infusion. BACKGROUND The degree of video intensity (VI) disparity in myocardial beds supplied by stenosed and normal coronary arteries can be used to quantify sten...

متن کامل

Qualitative and Quantitative Contrast‐Enhanced Ultrasonographic Assessment of Cerulein‐Induced Acute Pancreatitis in Dogs

BACKGROUND Acute pancreatitis (AP) is the most common disease of the canine exocrine pancreas, and accurate noninvasive diagnosis is challenging. HYPOTHESIS/OBJECTIVES To determine the feasibility of using quantitative contrast-enhanced ultrasonography (CEUS) to detect pancreatic perfusional changes in cerulein-induced AP in dogs. ANIMALS Six adult female Beagles. METHODS Each dog receive...

متن کامل

Pharmacokinetics Alterations of Midazolam Infusion versus Bolus Administration in Mechanically Ventilated Critically Ill Patients

There is no randomized study carried out in order to compare their pharmacokinetic parameters although midazolam, as a sedative, has been widely administered via continuous infusion as well as intermittent bolus doses in mechanically ventilated critically ill patients. We prospectively investigated the effect of these two principal methods on pharmacokinetic parameters in 23 of mentioned patien...

متن کامل

Pharmacokinetics Alterations of Midazolam Infusion versus Bolus Administration in Mechanically Ventilated Critically Ill Patients

There is no randomized study carried out in order to compare their pharmacokinetic parameters although midazolam, as a sedative, has been widely administered via continuous infusion as well as intermittent bolus doses in mechanically ventilated critically ill patients. We prospectively investigated the effect of these two principal methods on pharmacokinetic parameters in 23 of mentioned patien...

متن کامل

بروز ترومبوسیتوپنی ناشی ازهپارین، در دو روش تجویز داخل وریدی در بیماران با سندرم حاد کرونری

  Incidence of Thrombocytopenia Induced by Two Methods of Intravenous Heparin injection in Patients with Acute Coronary Syndrome.     H. Nough MD1* , A. Khodadadi Zadeh MSc2, M. Aref 3, A. Esmaieli ‌ Nadimi MD1     1- Assisstant Professor of Cardiology, University of Medical Sciences, Rafsanjan, Iran   2- Academic Member, Dept. of Nursing, Faculty of Nursing Midwifery, University of Medical Sci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 75  شماره 

صفحات  -

تاریخ انتشار 2013