Reliability of central venous pressure as a measure of changes in left sided intracardiac pressures.
نویسندگان
چکیده
Intracardiac pressures were simultaneously recorded in all cardiac chambers in anesthetized intact dogs during periods of volume overload produced by infusion of a blood saline mixture. The right and left intracardiac pressures increased simultaneously during the interval of infusion with the left side greater than the right side. The administration of a positive myocardial inotropic drug resulted in a corresponding right and left sided decrease in intracardiac pressures. The mean pressure increase in the left atrium was reliably predicted from simultaneous changes in the right atrial pressure. Tbe pressure change in the right atrium when 2 mm are added to adjust for differences in zero reference and then multiplied by two was approximately equivalent to concurrent changes in left atrial pressure.
منابع مشابه
Right and left heart pressures in acute myocardial infarction.
AUTHORS' SYNOPSIS In dogs the effects of acute myocardial infarction (AMI) on right and left heart pressure relationships were studied. Right atrial pressure was a poor predictor of left heart pressures. Pulmonary artery end-diastolic, left atrial, and left ventricular end-diastolic pressures tended to equalize in normals (except with tachycardia) and after AMI. In a previously scarred left ven...
متن کاملAccurate placement of central venous catheters using a 16-cm catheter.
We determine if use of 16-cm central venous catheters (CVC) minimizes dangerous intracardiac catheter placements. We conducted a prospective study in a large community teaching hospital. Consecutive patients (n = 127) who required a CVC via either the internal jugular (IJV) or the subclavian vein (SCV) were assessed using 16 (n = 102) or 20-cm (n = 25) catheters. The main outcome measurements w...
متن کاملCardiovascular pressures with venous gas embolism and decompression.
Venous gas embolism (VGE) is reported with decompression to a decreased ambient pressure. With severe decompression, or in cases where an intracardiac septal defect (patent foramen ovale) exists, the venous bubbles can become arterialized and cause neurological decompression illness. Incidence rates of patent foramen ovale in the general population range from 25-34% and yet aviators, astronauts...
متن کاملPulmonary artery catheterization and wedge pressure measurement in the general intensive therapy unit.
Central venous pressure measurement may be misleading in selective left heart failure and in patients with high pulmonary vascular resistance. More direct information about pulmonary venous pressure and left heart filling pressures may be obtained by catheterization of the pulmonary artery with flow-directed balloon catheters. The use of such catheters, without radiographic control, by those in...
متن کاملDetermination of Central Venous Pressure from Intraocular Pressure
Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 62 4 شماره
صفحات -
تاریخ انتشار 1972