An immobilization and localization technique for SRT and IMRT of intracranial tumors
نویسندگان
چکیده
A noninvasive localization and immobilization technique that facilitates planning and accurate delivery of both intensity modulated radiotherapy (IMRT) and linac based stereotactic radiotherapy (SRT) of intracranial tumors has been developed and clinically tested. Immobilization of a patient was based on a commercially available Gill-Thomas-Cossman (GTC) relocatable frame. A stereotactic localization frame (LF) with the attached NOMOS localization device (CT pointer) was used for CT scanning of patients. Thus, CT slices contained fiducial marks for both IMRT and SRT. The patient anatomy and target(s) were contoured on a stand-alone CT-based imaging system. CT slices and contours were then transmitted to both IMRT and SRT treatment planning systems (TPSs) for concurrent development of IMRT and SRT plans. The treatment method that more closely approached the treatment goals could be selected. Since all TPSs used the same contour set, the accuracy of competing treatment plans comparison was improved. SRT delivery was done conventionally. For IMRT delivery patients used the SRT patient immobilization system. For the patient setup, the IMRT target box was attached to the SRT LF, replacing the IMRT CT Pointer. A modified and lighter IMRT target box compatible with SRT LF was fabricated. The proposed technique can also be used for planning and delivery of 3D CRT, thus improving its accuracy. Day-to-day reproducibility of the patient setup can be evaluated using a SRT Depth Helmet.
منابع مشابه
Stereotactic Radiosurgery/Radiotherapy: A Historical Review
"Stereotactic" is an exact radiotherapy treatment modality which implements invasive and non-invasive facilities for improving precise dose delivery. Stereotactic refers to three-dimensional localization of a specific point in space by a unique set of coordinates that relate to a fixed external reference frame. An accurate delivery of radiation is attainable using these techniques with high pre...
متن کاملComparative dosimetric evaluation of three-dimensional conformal and stereotactic radiotherapy for treatment of intracranial tumors.
AIMS To evaluate the dosimetric profile among three-dimensional conformal radiotherapy (3D-CRT) and stereotactic radiotherapy (SRT) for the treatment of intracranial tumors. MATERIALS AND METHODS Seventeen patients with intra cranial tumors of benign nature or low malignant potential were enrolled and planned for SRT as well as 3D-CRT. Dosimetric comparison between these two plans was done co...
متن کاملComprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film
Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...
متن کاملIntensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields
Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...
متن کاملThe use of EBT3 film and Delta4 for the dosimetric verification of EclipseTM treatment planning system in a heterogeneous chest phantom: an IMRT technique
Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...
متن کامل