Self-calibrating through-time spiral GRAPPA for real-time CMR
نویسندگان
چکیده
Background Through-Time non-Cartesian GRAPPA, a novel parallel imaging method for non-Cartesian trajectories, has recently been shown to provide real-time, free-breathing cardiac images with temporal resolutions of less than 35 ms per frame [Seiberlich N, et al. MRM 2011 Dec;66 (6):1682-8]. The drawback to this method is the need for several fully-sampled datasets for calibration stemming from the non-Cartesian nature of the data, which leads to a longer overall scan time. By acquiring interleaved spiral datasets and combining them to form fully-sampled datasets for the generation of the GRAPPA weights, as in TGRAPPA [Breuer FA, et al. MRM 2005 Apr;53(4):9815.], there is no need for additional calibration data. However, this interleaved calibration method poses the risk of increased artifacts if the temporal footprint of the calibration data is too long. The goal of this study is to test the extent to which self-calibrating through-time spiral GRAPPA can be used for real-time free-breathing CMR.
منابع مشابه
RT-GROG: parallelized self-calibrating GROG for real-time MRI.
A real-time implementation of self-calibrating Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) operator gridding for radial acquisitions is presented. Self-calibrating GRAPPA operator gridding is a parallel-imaging-based, parameter-free gridding algorithm, where coil sensitivity profiles are used to calculate gridding weights. Self-calibrating GRAPPA operator gridding's wei...
متن کاملImproved radial GRAPPA calibration for real-time free-breathing cardiac imaging.
To generate real-time, nongated, free-breathing cardiac images, the undersampled radial trajectory combined with parallel imaging in the form of radial GRAPPA has shown promise. However, this method starts to fail at high undersampling factors due to the assumptions that must be made for the purposes of calibrating the GRAPPA weight sets. In this manuscript, a novel through-time radial GRAPPA c...
متن کاملEvaluation of left ventricular ejection fraction using through-time radial GRAPPA
BACKGROUND The determination of left ventricular ejection fraction using cardiovascular magnetic resonance (CMR) requires a steady cardiac rhythm for electrocardiogram (ECG) gating and multiple breathholds to minimize respiratory motion artifacts, which often leads to scan times of several minutes. The need for gating and breathholding can be eliminated by employing real-time CMR methods such a...
متن کاملQuantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time Non-Cartesian GRAPPA
BACKGROUND The standard clinical acquisition for left ventricular functional parameter analysis with cardiovascular magnetic resonance (CMR) uses a multi-breathhold multi-slice segmented balanced SSFP sequence. Performing multiple long breathholds in quick succession for ventricular coverage in the short-axis orientation can lead to fatigue and is challenging in patients with severe cardiac or ...
متن کاملThrough-Time Spiral GRAPPA for Real-Time Cardiac Imaging
Introduction: Accelerated data acquisition followed by parallel imaging reconstruction has been used in cardiac imaging to reduce imaging times and avoid artifacts due to motion. Coupled with non-Cartesian trajectories, such parallel imaging techniques can yield images with high acceleration factors with little residual aliasing. Recently, a method has been proposed which improves the radial GR...
متن کامل