Do commonly used ventilator settings for mechanically ventilated adults have the potential to embed secretions or promote clearance?
نویسندگان
چکیده
BACKGROUND Intubation and mechanical ventilation can impair mucociliary clearance and cause secretion retention, airway occlusion, atelectasis, and pneumonia. Animal and laboratory work has demonstrated that mechanical ventilator settings can generate a flow bias (inspiratory or expiratory) that may result in mucus movement either away from the ventilator (deeper into the lungs) or toward the ventilator (toward the mouth), respectively. An absolute difference of 17 L/min, and a relative difference of ≥ 10%, between the expiratory and inspiratory flow have been reported as thresholds for mucus movement. METHODS We measured baseline peak inspiratory and expiratory flows during quiet mechanical ventilation in a convenience sample of 20 intubated and ventilated adult patients. RESULTS Nineteen patients had an inspiratory flow bias of ≥ 10%. Eight patients had an absolute mean inspiratory flow bias of ≥ 17 L/min. CONCLUSIONS Commonly used mechanical ventilator settings generate an inspiratory flow bias that may promote secretion retention.
منابع مشابه
Secretion management in the mechanically ventilated patient.
Secretion management in the mechanically ventilated patient includes routine methods for maintaining mucociliary function, as well as techniques for secretion removal. Humidification, mobilization of the patient, and airway suctioning are all routine procedures for managing secretions in the ventilated patient. Early ambulation of the post-surgical patient and routine turning of the ventilated ...
متن کاملHyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: a randomised crossover trial.
QUESTION Is ventilator-induced hyperinflation in sidelying more effective than sidelying alone in removing secretions and improving respiratory mechanics in ventilated patients with pulmonary infection? DESIGN Randomised crossover trial with concealed allocation and intention-to-treat analysis. PARTICIPANTS 30 mechanically ventilated patients with pulmonary infection in an adult intensive c...
متن کاملVentilator graphics and respiratory mechanics in the patient with obstructive lung disease.
Obstruction of the large and small airways occurs in several diseases, including asthma, chronic obstructive pulmonary disease, cystic fibrosis, bronchiectasis, and bronchiolitis. This article discusses the role of ventilator waveforms in the context of factors that contribute to the development of respiratory failure and acute respiratory distress in patients with obstructive lung disease. Dis...
متن کاملFlexible Bronchoscopy Is Safe and Effective in Adult Subjects Supported With Extracorporeal Membrane Oxygenation.
BACKGROUND Previous studies have demonstrated the safety of flexible bronchoscopy (FB) in mechanically ventilated subjects. However, the safety of FB in adult subjects receiving extracorporeal membrane oxygenation (ECMO) has not been described previously. METHODS A retrospective review was conducted of all adult subjects who underwent FB while receiving ECMO support at the University of Alaba...
متن کاملEffects of manual hyperinflation and suctioning in respiratory mechanics in mechanically ventilated patients with ventilator-associated pneumonia.
Ventilator-associated pneumonia results from bacterial colonisation of the aerodigestive tract or aspiration of contaminated secretions into the lower airways. As a consequence of infection of the lung parenchyma and alveolitis, accumulation of inflammatory exudates and infiltration of airway mucosa can lead to unfavourable respiratory mechanics in ventilator-associated pneumonia. Tracheal suct...