Upgraded Alignment Control for the Diii–d Thomson Scattering Laser System

نویسنده

  • C.-L. HSIEH
چکیده

The Thomson scattering system measures electron density and temperature with the aid of eight pulsed ND-YAG lasers on the DIII–D Tokamak. DIII–D is the United States National Fusion Facility for magnetic confinement fusion experiments. The Thomson system probes the tokamak in three separate regions. The measurements from the different regions produce density and temperature profiles during plasma discharges. The laser light must be aimed through the DIII–D vessel with 1 mm of spatial accuracy to produce correct density profiles. Recent upgrades to the alignment system reduce the effort required to perform the initial alignment before plasma operations, and improve the monitoring and control of the alignment. The upgraded hardware allows for monitoring and control of the alignment from the Thomson control room during operations and from multiple key locations along the 35 m long optical path. In future upgrades the adjustment of the mirrors will be automated by utilizing feedback from a computerized beam analysis system that relays beam position information to the control computer. The newly established methods for setting up the YAG beams using the CCD cameras instead of burn paper offer a faster and more reliable method to prepare the system for plasma-operations. The YAG lasers are aimed with repeatable accuracy and any drifts can be detected and corrected during the small warm up period before each shot.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Upgraded Calibrations of the Thomson System at Diii-d

The DIII–D Thomson system measures electron density and temperature with eight pulsed ND:YAG lasers along three paths through the plasma vessel. The components of the Thomson system are absolutely calibrated so the measurements can be combined into a single profile from a normalized plasma radius (p) of about 0.1 to the edge of the plasma. A monochromator calibration and opto-electronic calibra...

متن کامل

Diii – D Thomson Scattering Diagnostic Data Acquisition , Processing , and Analysis Software

One of the diagnostic systems critical to the success of the DIII–D tokamak experiment is the Thomson scattering diagnostic. This diagnostic is unique in that it measures local electron temperature and density: 1) at multiple locations within the tokamak plasma; and 2) at different times throughout the plasma duration. Thomson “raw” data are digitized signals of scattered light, measured at dif...

متن کامل

Large area avalanche photodiode detector array upgrade for a ruby-laser Thomson scattering system

A low-cost upgrade has been implemented on the Madison Symmetric Torus ~MST! ruby-laser Thomson scattering ~TS! system to increase spectral coverage and substantially improve the signal-to-noise ratio ~SNR!. The spectral resolution has been increased from five channels on the long-wavelength side to an 11-channel system, which covers both sides of the laser line. Coverage on both sides of the s...

متن کامل

Pulse-burst laser systems for fast Thomson scattering (invited).

Two standard commercial flashlamp-pumped Nd:YAG (YAG denotes yttrium aluminum garnet) lasers have been upgraded to "pulse-burst" capability. Each laser produces a burst of up to 15 2 J Q-switched pulses (1064 nm) at repetition rates of 1-12.5 kHz. Variable pulse-width drive (0.15-0.39 ms) of the flashlamps is accomplished by insulated gate bipolar transistor (IGBT) switching of electrolytic cap...

متن کامل

An upgrade of the magnetic diagnostic system of the DIII-D tokamak for non-axisymmetric measurements.

The DIII-D tokamak magnetic diagnostic system [E. J. Strait, Rev. Sci. Instrum. 77, 023502 (2006)] has been upgraded to significantly expand the measurement of the plasma response to intrinsic and applied non-axisymmetric "3D" fields. The placement and design of 101 additional sensors allow resolution of toroidal mode numbers 1 ≤ n ≤ 3, and poloidal wavelengths smaller than MARS-F, IPEC, and VM...