Analysis of sphingoid bases by reversed-phase high performance liquid chromatography.
نویسندگان
چکیده
A reversed-phase high performance liquid chromatography (HPLC) technique was developed for the analysis of sphingoid bases as their biphenylcarbonyl derivatives. The sphingoid bases (0.3-500 nmol) obtained from sphingolipids after hydrolysis were quantitatively derivatized with biphenylcarbonyl chloride at room temperature for 90 min. After removal of excess reagent by partitioning, the derivatized products were quantitatively analyzed on a reversed-phase HPLC column, with detection at 280 nm. A mixture of biphenylcarbonyl C18-5-hydroxysphinganine, C18-erythro and threo sphingenine, and sphinganine, C18-5-O-methyl and 3-O-methyl sphingenine, C20-sphingenine, sphingosyl phosphorylcholine, and psychosine and were well resolved from one another. The method was employed for the analysis of less than nanomole quantities of sphingoid bases from sphingomyelin and cerebrosides.
منابع مشابه
Simulataneous Analysis of Trimethoprim and Sulphamethoxazole Drug Combinations in Dosage Forms by High Performance Liquid Chromatography
A sensitive high performance liquid chromathography (HPLC) analytical procedure was developed for the quantitive determination of trimethoprim (TM* and sulphamethoxazole (SM) in commercial dosage forms. C18 analytical column (stainless steel, 25 cm * 4.6 mm i.d.) was packed with 5-*m particles of the reversed phase material and used for assays. Mobile phase containing 0.025 M sodium phosphate...
متن کاملReversed-phase Salt Assisted Liquid-liquid Extraction: A New Technique for Preconcentration and Determination of Crocin in Herbal Medicines by HPLC
A reversed-phase salt assisted liquid-liquid extraction (RP-SALLE) method was developed for the preconcentration and determination of trace crocin in herbal medicines by high-performance liquid chromatography (HPLC). In developed method, the roles of the aqueous and organic phases are inverted so that the analyte is extracted from the organic into the aqueous phase after salt addition and phase...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملA simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of lipid research
دوره 24 10 شماره
صفحات -
تاریخ انتشار 1983