Evaluation of Two Systems for Fundus-Controlled Scotopic and Mesopic Perimetry in Eye with Age-Related Macular Degeneration
نویسندگان
چکیده
PURPOSE The purpose of this study was to evaluate and compare the MP-1S (Nidek Technologies, Padova, Italy) and the S-MAIA (CenterVue, Padova, Italy) for mesopic and scotopic fundus-controlled perimetry (FCP) in age-related macular degeneration (AMD). METHODS Eleven eyes from 11 patients underwent mesopic and, after 30 minutes of dark adaptation, scotopic (MP-1S: Goldmann V, 200 ms, background luminance 0.0032 cd/m2; S-MAIA: Goldman III, 200 ms, background luminance <0.0001 cd/m2) FCP. For the S-MAIA device, cyan (505 nm) and red (627 nm) scotopic FCP were performed. For both devices, a grid of 56 stimulus points covering 16° of the central macula was used. Examination time, fixation stability, and threshold values were analyzed. RESULTS The upper end of the dynamic range (≤4 dB of lowest threshold) was frequently reached by the MP-1S for mesopic testing (median 34 of 56 stimuli), while threshold values within the lower 4 dB of the dynamic range were occasionally found with the S-MAIA for scotopic testing (median 3 for cyan, median 2 for red). After correction of the stimulus intensity for the S-MAIA results, the median difference for all stimuli between both devices for mesopic testing was -2.0 dB (interquartile range [-4;0], range -14 to 6). CONCLUSIONS The results indicate that robust testing of mesopic and scotopic function is feasible with both devices in patients with AMD, although both devices are susceptible to floor and ceiling effects. TRANSLATIONAL RELEVANCE The interpretation and particularly the comparison of both scotopic and mesopic FCP results between the MP-1S and the S-MAIA in AMD eyes need to consider variable susceptibility of floor and ceiling effects. Further software updates are desirable as FCP captures visual functional loss that is not noted with best-corrected central visual acuity and is important for clinical trials in AMD.
منابع مشابه
Structure-Function Analysis in Patients With Intermediate Age-Related Macular Degeneration.
Purpose To examine the topographic correlation between retinal morphology and retinal sensitivity by mesopic and scotopic fundus-controlled perimetry (FCP) in eyes with intermediate AMD. Methods Thirty-five eyes from 32 patients (mean age 70.9 years) and 29 age-matched controls prospectively underwent spectral-domain optical coherence tomography (SD-OCT) imaging. Mesopic (Goldman III, 200 ms,...
متن کاملEffective Dynamic Range and Retest Reliability of Dark-Adapted Two-Color Fundus-Controlled Perimetry in Patients With Macular Diseases.
Purpose To determine the effective dynamic range (EDR), retest reliability, and number of discriminable steps (DS) for mesopic and dark-adapted two-color fundus-controlled perimetry (FCP) using the S-MAIA (Scotopic-Macular Integrity Assessment) "micro-perimeter." Methods In this prospective cross-sectional study, each of the 52 eyes of 52 subjects with various macular diseases (mean age 62.0 ...
متن کاملScotopic Microperimetry in the Early Diagnosis of Age-Related Macular Degeneration: Preliminary Study
BACKGROUND Recent clinical studies have shown that, in some degenerative retinal diseases, like age-related macular degeneration (AMD), the sensitivity of the rods decreases more rapidly than the sensitivity of the cones. The aim of this study was to evaluate if there is a correlation between the presence of hard drusen at the macular level and the rod damage responsible for the reduction in sc...
متن کاملDecision Support System for Age-Related Macular Degeneration Using Convolutional Neural Networks
Introduction: Age-related macular degeneration (AMD) is one of the major causes of visual loss among the elderly. It causes degeneration of cells in the macula. Early diagnosis can be helpful in preventing blindness. Drusen are the initial symptoms of AMD. Since drusen have a wide variety, locating them in screening images is difficult and time-consuming. An automated digital fundus photography...
متن کاملAxial and Posterior Wall Thickness Elastic Modulus of Eyes in Age-related Macular Degeneration (ARMD) Patients Compared to Healthy Individuals Using Ultrasound Images
Background & Aims: Age-related macular degeneration (ARMD) is one of the common retina disorders that can lead to loss of vision by increase in age. In this study, the efficacy of a non-invasive ultrasound technique for the evaluation of alastic properties of eye in the diagnosis of ARMD has been evaluated. Methods: For estimation of the elastic modulus of eye, spatial loading system designed a...