Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial.

نویسندگان

  • Jean Fajadet
  • William Wijns
  • Gert-Jan Laarman
  • Karl-Heinz Kuck
  • John Ormiston
  • Thomas Münzel
  • Jeffrey J Popma
  • Peter J Fitzgerald
  • Raoul Bonan
  • Richard E Kuntz
چکیده

BACKGROUND The use of the Endeavor stent might reduce restenosis and stent thrombosis at 9 months. METHODS AND RESULTS Patients (n = 1197) treated for single coronary artery stenosis were enrolled in a prospective, randomized, double-blind study and randomly assigned to receive the Endeavor zotarolimus-eluting phosphorylcholine polymer-coated stent (n = 598) or the same bare metal stent but without the drug or the polymer coating (n = 599). The 2 groups were well matched in baseline characteristics. Diabetes was present in 20.1% of patients; the mean reference vessel diameter was 2.75 mm; and the mean lesion length was 14.2 mm. The primary end point of target vessel failure at 9 months was reduced from 15.1% with the bare metal stent to 7.9% with the Endeavor (P = 0.0001), and the rate of major adverse cardiac events was reduced from 14.4% with the bare metal stent to 7.3% with the Endeavor (P = 0.0001). Target lesion revascularization was 4.6% with Endeavor compared with 11.8% with the bare metal stent (P = 0.0001). The rate of stent thrombosis was 0.5% with the Endeavor, which was not significantly different from 1.2% with the bare metal stent. In 531 patients submitted to angiographic follow-up, late loss was reduced from 1.03 +/- 0.58 to 0.61 +/- 0.46 (P < 0.001) in stent and from 0.72 +/- 0.61 to 0.36 +/- 0.46 (P < 0.001) in segment. The rate of in-segment restenosis was reduced from 35.0% to 13.2% with Endeavor (P < 0.0001). There was no excessive edge stenosis, aneurysm formation, or late acquired malapposition by intravascular ultrasound imaging. Differences in clinical outcome were maintained at 12 and 24 months (P < 0.0001). CONCLUSIONS Compared with bare metal stents, the Endeavor stent is safe and reduces the rates of clinical and angiographic restenosis at 9, 12, and 24 months.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomized comparison of the Endeavor zotarolimus-eluting stent versus the TAXUS paclitaxel-eluting stent in de novo native coronary lesions 12-month outcomes from the ENDEAVOR IV trial.

OBJECTIVES The ENDEAVOR IV (Randomized Comparison of Zotarolimus-Eluting and Paclitaxel-Eluting Stents in Patients with Coronary Artery Disease) trial evaluated the safety and efficacy of the zotarolimus-eluting stent (ZES) compared with the paclitaxel-eluting stent (PES). BACKGROUND First-generation drug-eluting stents have reduced angiographic and clinical restenosis, but long-term safety r...

متن کامل

The "final" 5-year follow-up from the ENDEAVOR IV trial comparing a zotarolimus-eluting stent with a paclitaxel-eluting stent.

OBJECTIVES This study sought to report the final 5-year outcomes of the ENDEAVOR IV (A Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) trial comparing the Endeavor zotarolimus-eluting stent (E-ZES) (Medtronic, Santa Rosa, California) with the T...

متن کامل

Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from...

متن کامل

Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers

Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from t...

متن کامل

The "final voyage" of the Endeavor stent.

The “final” 5-year outcomes of combined trials with the Endeavor zotarolimus-eluting stent (E-ZES) by Kandzari et al. (1), published in this issue of JACC: Cardiovascular Interventions, might be considered a companion to the Kirtane et al. (2) publication in the issue last month of JACC: Cardiovascular Interventions, which reported on the “final” 5-year follow-up of the ENDEAVOR IV (A Randomize...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 114 8  شماره 

صفحات  -

تاریخ انتشار 2006