Feature Selection for Partial Discharge Severity Assessment in Gas-Insulated Switchgear Based on Minimum Redundancy and Maximum Relevance

نویسندگان

  • Ju Tang
  • Miao Jin
  • Fuping Zeng
  • Siyuan Zhou
  • Xiaoxing Zhang
  • Yi Yang
  • Yan Ma
چکیده

Scientific evaluation of partial discharge (PD) severity in gas-insulation switchgear (GIS) can assist in mastering the insulation condition of in-service GIS. Limited theoretical research on the laws of PD deterioration leads to a finite number of evaluation features extracted and subjective features selected for PD severity assessment. Therefore, this study proposes a minimum-redundancy maximum-relevance (mRMR) algorithm-based feature optimization selection method to realize the scientific and reasonable choice of PD severity features. PD ultra-high frequency data of varying severities are produced by simulating four typical insulation defects in GIS, which are then collected in the lab. A 16-dimension feature set describing PD original characteristics is abstracted in phase-resolved partial discharge (PRPD) mode, and the more informative evaluation feature set characterizing PD severity is further excavated by the mRMR method. Finally, a support vector machine (SVM) algorithm is employed as the classifier for intelligent evaluation to compare the evaluation effects of PD severity between the feature set selected by mRMR and the feature set is composed of discharge times, amplitude value, and time intervals obtained traditionally based on discharge change theory. The proposed comparison test showed the effectiveness of the mRMR method in informative feature selection and the accuracy of PD severity assessment for all defined defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using SF6 Decomposed Component Analysis for the Diagnosis of Partial Discharge Severity Initiated by Free Metal Particle Defect

The decomposition characteristics of a SF6 gas-insulated medium were used to diagnose the partial discharge (PD) severity in DC gas-insulated equipment (DC-GIE). First, the PD characteristics of the whole process were studied from the initial PD to the breakdown initiated by a free metal particle defect. The average discharge magnitude in a second was used to characterize the PD severity and th...

متن کامل

A New Framework for Distributed Multivariate Feature Selection

Feature selection is considered as an important issue in classification domain. Selecting a good feature through maximum relevance criterion to class label and minimum redundancy among features affect improving the classification accuracy. However, most current feature selection algorithms just work with the centralized methods. In this paper, we suggest a distributed version of the mRMR featu...

متن کامل

Status Review on Gas Insulated Switchgear Partial Discharge Diagnostic Technique for Preventive Maintenance

Gas insulated switchgear (GIS) plays a vital role in high voltage transmission of electrical energy due to its advantages of high reliability and performance, compact in dimensions and outstanding compatibility with the environment. It uses sulphur hexafluoride gas as its insulant and coolant because of its high dielectric strength and excellent arc quenching ability. Gas insulated switchgear i...

متن کامل

Mental Arithmetic Task Recognition Using Effective Connectivity and Hierarchical Feature Selection From EEG Signals

Introduction: Mental arithmetic analysis based on Electroencephalogram (EEG) signal for monitoring the state of the user’s brain functioning can be helpful for understanding some psychological disorders such as attention deficit hyperactivity disorder, autism spectrum disorder, or dyscalculia where the difficulty in learning or understanding the arithmetic exists. Most mental arithmetic recogni...

متن کامل

Chemical by-Product Diagnostic Technique for Gas Insulated Switchgear Condition Monitoring

Chemical by product diagnostic technique is an efficient, cost-effective and reliable diagnostic technique for gas insulate switchgear condition monitoring in view of its high sensitivity and antiinternal and external electromagnetic interference and noise. In this research paper, coaxial simulated gas insulated switchgear chamber and four different types of artificial defect were designed to c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017