IDEAL at 7T in Mice Using Asymmetric Spin Echo and Gradient Echo Acquisitions
نویسندگان
چکیده
An asymmetric spin echo (aSE) technique was developed to produce uniform, robust fat-water separation in mice at 7T using Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-squares estimation method (IDEAL). The aSE technique had superior image quality as compared to gradient echo IDEAL estimation. Both the spin echo and gradient echo IDEAL techniques resulted in more accurate fat-water separation than chemical shift selective imaging. A vectorized IDEAL reconstruction was used to speed up the estimation by using multiple CPUs and graphics cards.
منابع مشابه
اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملOptimisation of the combined gradient echo/spin echo (GESE) sequence for the measurement of T2 at 7.0 T
The combined gradient echo/spin echo (GESE) sequence has been used to measure T2 and T2* simultaneously in the brain at 7T in both healthy volunteers and patients . GESE is particularly useful at 7T as it is insensitive to RF pulse errors since errors in either of the pulse flip angles will cause constant attenuation of all the echoes, leading to a simple reduction in SNR, and it has a low SAR....
متن کاملReduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla.
Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhomogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of ...
متن کاملReduced SAR with BASE Sequence at 7 Tesla
Introduction: To reduce measurement time, sequences are required which either significantly reduce the repetition time or acquire several echoes within each excitation. Among those the Turbo Spin Echo (TSE) is widely used today on clinical scanners at typical field strength of 1.5T to 3T. The step towards 7T provides a significantly higher MR signal potentially allowing for decreased scan time ...
متن کاملUltra Short Gradient Echo Imaging of the Prostate at 7T
INTRODUCTION: The purpose of this study was to investigate, for the first time, the potential of ultra short TE (UTE) imaging the prostate at 7T, using a 3D radial acquisition of gradient echoes (UTE-GRE) (1). There are several unique characteristics of this sequence which create both challenges and opportunities for body imaging at 7T. First, UTE-GRE acquisitions would greatly reduce the treme...