Acoustic rhinometry: validation by three-dimensionally reconstructed computer tomographic scans.

نویسندگان

  • H Terheyden
  • S Maune
  • J Mertens
  • O Hilberg
چکیده

The aim of the present study was a validation of acoustic rhinometry (AR) by computed tomography (CT). Six healthy subjects were examined by CT and AR. The CT data were processed in a computer program (AutoCAD), and a virtual three-dimensional model of each nasal cavity was constructed. This model permitted an individual prediction of the center line of the sound wave propagation through the air volume of the nasal cavity with the cross-sectional areas oriented perpendicularly to this line. The area-distance curves derived from AR and CT were compared. Linear regression analysis revealed a reasonable agreement of AR and CT in the anterior nose below a mean of 6 cm distance from the nostrils [r = 0.839, P < 0.01, m = 1.123, b = -0.113 (AR = m x CT + b)]. The measuring accuracy using CT as gold standard revealed a mean error at the nasal valve of <0.01 cm(2) (4.52%) and at the nasal isthmus of 0.02 cm(2) (1. 87%). Beyond 6 cm, the correlation decreased (r = 0.419), and overestimation of the true area occurred (>100%). In conclusion, the measurements were reasonably accurate for diagnostic use up to the turbinate head region. Certain factors induce an overestimation of the true areas beyond this region. However, these factors are constant and reproducible in a single subject, and intraindividual comparative measurements are possible beyond the turbinate head region.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Value of acoustic rhinometry for measuring nasal valve area.

OBJECTIVE To assess the validity of acoustic rhinometry for measuring nasal valve area in human subjects. STUDY DESIGN A comprehensive study that compared acoustic rhinometry data with computed tomography findings from scans obtained perpendicular to the acoustic axis and perpendicular to the floor of the nose. METHODS Fifty nasal passages of 25 healthy adults with no nasal disease were exa...

متن کامل

Acoustic rhinometry and computed tomography scans for the diagnosis of nasal septal deviation, with clinical correlation.

OBJECTIVE The aim in this study was to analyze the efficiency and reliability of acoustic rhinometry (AR) readings in recognition of nasal septal deviation. METHOD We compared 24 patients' AR readings with their sinus CT scans. The patient data were analyzed by comparison with normative data, area, and percentage differences between the two sides. Additionally, the data further analyzed by re...

متن کامل

Assessment of septoplasty effectiveness using acoustic rhinometry and rhinomanometry

Introduction: Septal deviation is the chief cause of chronic nasal obstruction. In order to treat such cases, nasal septoplasty surgery is usually performed based on patient complaints and a surgeon's examination, both of which are subjective. This study aims at using the objective parameters of acoustic rhinometry and rhinomanometry to evaluate the effectiveness of septoplasty surgery.   Ma...

متن کامل

Remodeling of living human nasal cavity under the assistance of acoustic rhinometry technique

Acoustic rhinometry could numerically describe upper airway condition of air draft by drawing a graph plotting the distance from the nostril vs. the crosssectional area. Some decreases on the graph correspond to the typical anatomic structures of human nasal cavity. The 3-dimensional, computing fluid dynamic model of the same person was developed based on computed tomography scans. The veracity...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 89 3  شماره 

صفحات  -

تاریخ انتشار 2000