The Comparison of Clinical, Histopathological and some Hemodynamic Effects of Spinal Anesthesia Applied in Dogs Through Bupivacaine HCl and Ropivacaine HCl in Two Different Concentrations
نویسنده
چکیده
The aim of this study was to evaluate the side effects of local and systemic clinical, histopathological and hemodynamics by use of isobaric and hyperbaric bupivacaine in different concentrations during spinal anesthesia which has been a common use within the past few years. The study material consisted of 23 healthy stray dogs with dissimilar sex, age and body weight as well as bupivacaine hydrochloride containing Marcaine® %0.5 (Astra Zenaca, Turkey) and Marcaine® Spinal Heavy %0.5 (Astra Zenaca, Turkey), and ropivacaine hydrochloride containing Naropin® 7.5mg/ml (Astra Zenaca, Germany) so as to create the state of spinal anesthesia. A total of 5 different groups were formed where each study group consisted of 5 dogs and the control group consisted of 3 dogs. The groups were as follows: Aa (Marcaine), Ab (Marcaine® Spinal Heavy), Ba (Naropin®), Bb (Naropin® + Dekstroz) and C (Dekstroz). During the anesthesia; blood pressure, pulse and respiratory rates were measured in all groups. Besides, needle punctures were applied from time to time. The animals were euthanized following a one-week long hospitalization. Then, the parts of the spinal cords on which injections were applied were taken off and investigated histopathologically. In this study no significant were observed with regard to the use of ropivacaine HCl and bupivacaine HCl and their clinical, hemodynamic and histopathologic side effects; on the other hand, bupivacaine HCl was found to be considerably superior to ropivacaine HCl regarding the anesthesia duration and depth.
منابع مشابه
Comparison of the Effect of Intrathecal Bupivacaine with Intrathecal Ropivacaine on Hemodynamic of Patients under Elective Caesarean Section
Background and Objectives: The correct management of delivery and anesthesia hs important for maternal and fetal health outcome during cesarean section. The aim of this study was to compare the effect os spinal anesthesia with bupivacaine and ropivacaine on the hemodynamic parameters of pregnant women during cesarean section. Methods: This study was a randomized double blinded clinical trial o...
متن کاملComparison of Spinal Anesthesia in L3-L4 and L4-L5 on Sensory-Motor Block Level and Hemodynamic Status in Cesarean Section
Background and Objective: The injection site in spinal anesthesia is one of the factors that can affect the height of the sensory block. This clinical trial study aimed to compare the effect of spinal anesthesia at L3-L4 and L4-L5 on the level of sensory-motor block and hemodynamic status in cesarean section. Materials and Methods: Seventy patients undergoing elective cesarean section and rece...
متن کاملEffects of intrathecal anesthesia with different concentrations and doses on spinal cord, nerve roots and cerebrospinal fluid in dogs.
OBJECTIVE To investigate the effects of intrathecal anesthesia with bupivacaine, levobupivacaine and ropivacaine hydrochloride at different doses on the spinal cord, nerve roots and cerebrospinal fluid (CSF) in dogs. METHODS Forty-two mongrel dogs were randomly divided into normal saline group (C; 2 ml), 0.5% (B1) and 0.75% (B2) bupivacaine hydrochloride groups (2 ml), 0.5% (L1) and 0.75% (L2...
متن کاملبررسی اثرات افزودن فنتانیل به بوپیواکائین در بیحسی نخاعی بیماران وابسته به تریاک
Introduction: Spinal anesthesia in opium-addicted patients can be associated with many complications. Hence, this study aimed to investigate sensory and motor block characteristics, duration of postoperative analgesia, hemodynamic and side effects by adding Fentanyl to bupivacaine in spinal Anesthesia of opium-addicted patients. Methods: In a double-blind randomized clinical trial, 60 American...
متن کاملبی حسی نخاعی برای عمل جراحی سزارین: مقایسه بوپی واکا یین هیپرباریک با ایزوباریک
Aims and Background: The baricity of the solutions used for spinal anesthesia significantly affects the distribution and dissemination of local anesthetics into the spinal space. The purpose of this study was to compare the effects of hyperbaric and isobaric bupivacaine for spinal anesthesia in cesarean section. Materials and Methods: This was a randomized double blind clinical trial on sixt...
متن کامل