Optimal Timing for In Vivo H-MR Spectroscopic Imaging of the Human Prostate at 3T
نویسندگان
چکیده
Proton MR spectroscopic imaging (H-MRSI) of the human prostate, which has an interesting clinical potential, may be improved by increasing the magnetic field strength from 1.5T to 3T. Both theoretical and practical considerations are necessary to optimize the pulse timing for spectroscopic imaging of the human prostate at 3T. For in vivo detection of the strongly coupled spin system of citrate, not only should the spectral shape of the signal be easy to identify, but the timing used should produce MR signals at reasonably short echo times (TEs). In this study the spectral shape of the methylene protons of citrate was simulated with density matrix calculations and checked with phantom measurements. Different calculated optimal spectral shapes were measured in patients with prostate cancer with a 2D spectroscopic imaging sequence. T1 and T2 relaxation times were calculated for citrate and choline, the two major metabolites of interest in the prostate. We conclude that the optimum timing for in vivo point-resolved spectroscopy (PRESS) imaging at 3T is an interpulse timing sequence of 90° 25 ms 180° 37.5 ms 180° 12.5 ms echo. A short repetition time (TR) of 750 ms partially saturates choline signals, but increases the SNR per unit time for citrate, and accommodates a maximum number of weighted averages of an elliptically sampled k-space for accurate localization and minimal contamination of the individual spectra. This is illustrated by means of a 3D spectroscopic imaging experiment in a complete prostate in vivo. Magn Reson Med 53:1268–1274, 2005. © 2005 Wiley-Liss, Inc.
منابع مشابه
Optimal timing for in vivo 1H-MR spectroscopic imaging of the human prostate at 3T.
Proton MR spectroscopic imaging ((1)H-MRSI) of the human prostate, which has an interesting clinical potential, may be improved by increasing the magnetic field strength from 1.5T to 3T. Both theoretical and practical considerations are necessary to optimize the pulse timing for spectroscopic imaging of the human prostate at 3T. For in vivo detection of the strongly coupled spin system of citra...
متن کاملHigh-speed 3T MR spectroscopic imaging of prostate with flyback echo-planar encoding.
Prostate MR spectroscopic imaging (MRSI) at 3T may provide two-fold higher spatial resolution over 1.5T, but this can result in longer acquisition times to cover the entire gland using conventional phase-encoding. In this study, flyback echo-planar readout trajectories were incorporated into a Malcolm Levitt's composite-pulse decoupling sequence (MLEV)-point-resolved spectroscopy sequence (PRES...
متن کاملOptimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...
متن کاملIn vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility.
(31)P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D (31)P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a (31)P endorectal coil was developed and c...
متن کاملMR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils
Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...
متن کامل