Ultrashort echo time (UTE) MRI for the assessment of caries lesions
نویسندگان
چکیده
OBJECTIVE Direct in vivo MRI of dental hard tissues by applying ultrashort echo time (UTE) MRI techniques has recently been reported. The objective of the presented study is to clinically evaluate the applicability of UTE MRI for the identification of caries lesions. METHODS 40 randomly selected patients (mean age 41 ± 15 years) were enrolled in this study. 39 patients underwent a conventional clinical assessment, dental bitewing X-ray and a dental MRI investigation comprising a conventional turbo-spin echo (TSE) and a dedicated UTE scan. One patient had to be excluded owing to claustrophobia. In four patients, the clinical treatment of the lesions was documented by intraoral pictures, and the resulting volume of the cavity after excavation was documented by dental imprints and compared with the MRI findings. RESULTS In total, 161 lesions were identified. 157 (97%) were visible in the UTE images, 27 (17%) in the conventional TSE images and 137 (85%) in the X-ray images. In total, 14 teeth could not be analysed by MR owing to artefacts caused by dental fillings. All lesions appear significantly larger in the UTE images as compared with the X-ray and TSE images. In situ measurements confirm the accuracy of the lesion dimensions as observed in the UTE images. CONCLUSION The presented data provide evidence that UTE MR imaging can be applied for the identification of caries lesions. Although the current data suggest an even higher sensitivity of UTE MRI, some limitations must be expected from dental fillings.
منابع مشابه
Ultrashort echo time MRI of pulmonary water content: assessment in a sponge phantom at 1.5 and 3.0 Tesla.
PURPOSE We aimed to develop a predictive model for lung water content using ultrashort echo time (UTE) magnetic resonance imaging (MRI) and a sponge phantom. MATERIALS AND METHODS Image quality was preliminarily optimized, and the signal-to-noise ratio (SNR) of UTE was compared with that obtained from a three-dimensional fast gradient echo (FGRE) sequence. Four predetermined volumes of water ...
متن کاملContrast enhanced ultrashort echo time MRI of the Achilles enthesis in normal volunteers and psoriatic arthritis
tendon showing internal structure. UTE subtraction image (left) consistent with fascicular structure. Ultrasound (right) shows smaller scale structure. Fig.2: Delayed post-contrast UTE image of the Achilles tendon of a patient with PsA shows focus of high signal intensity in the region of the enthesis (arrow) not present on pre-contrast UTE or conventional post-contrast MRI. Contrast enhanced u...
متن کاملMorphological MR imaging of the articular cartilage of the knee at 3 T—comparison of standard and novel 3D sequences
OBJECTIVES This study sought to compare various 3D cartilage sequences and to evaluate the usefulness of ultrashort TE (UTE) imaging, a new technique to isolate signal from the osteochondral junction. METHODS Twenty knees were examined at 3 T with 3D spoiled GRE (FLASH), double-echo steady-state (DESS), balanced SSFP, 3D turbo spin-echo (TSE), and a prototype UTE sequence. Two radiologists in...
متن کاملMultiecho Ultrashort TE (UTE) Imaging and T2* Mapping of Knee Cartilage
INTRODUCTION Magnetic resonance imaging has been used widely for the detection of cartilage lesions (1, 2). In addition to quantifying changes in cartilage morphology, such as thickness and volume, extensive studies have been performed on T1 and T2 quantification which reflect changes in biochemical composition of cartilage with early osteoarthritis (OA) (3-5). Short TE projection reconstructio...
متن کاملQuantitative contrast-enhanced MRI with superparamagnetic nanoparticles using ultrashort time-to-echo pulse sequences.
PURPOSE Conventional MRI using contrast agents is semiquantitative because it is inherently sensitive to extravoxular susceptibility artifacts, field inhomogeneity, partial voluming, perivascular effects, and motion/flow artifacts. Herein we demonstrate a quantitative contrast-enhanced MRI technique using ultrashort time-to-echo pulse sequences for measuring clinically relevant concentrations o...
متن کامل