A rapid, isocratic method for phospholipid separation by high-performance liquid chromatography.
نویسندگان
چکیده
A rapid, isocratic method for separating the most prevalent phospholipids by high-performance liquid chromatography is described. Baseline resolution of phosphatidylinositol, phosphatidylserine, phosphatidylethanolamine, phosphatidylcholine, lysophosphatidylcholine, and sphingomyelin is achieved in less than 40 min on a silica column. Lipids are injected in 10 microliter of chloroform-diethyl ether 1:2 (v/v) and eluted with a solvent mixture of acetonitrile-methanol-sulfuric acid 100:3:0.05 (v/v/v) at a flow rate of 1 ml/min. Neutral lipids and cardiolipin elute with the solvent front. Chromatography of a radioactive cell lipid extract indicates a recovery of better than 97%. The procedure is sensitive enough to permit the analysis of the main phospholipids present in a monolayer culture containing about 100 micrograms of cell protein.
منابع مشابه
A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملDeveloped Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کاملSeparation of polyprenyl phosphate oligomerhomologues by reversed-phase ion-pair high-performance liquid chromatography.
A simple and rapid method of reversed-phase ion-pair high-performance liquid chromatography (HPLC) with UV-detection on a common C(18) column in an isocratic mode with the addition of tetrabutylammonium phosphate for the separation of polyprenyl phosphate oligomerhomologues has been developed. The method was successfully applied to assay the composition of polyprenyl phosphates obtained from p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of lipid research
دوره 24 10 شماره
صفحات -
تاریخ انتشار 1983