Randomized Trial of Conventional Transseptal Needle Versus Radiofrequency Energy Needle Puncture for Left Atrial Access (the TRAVERSE‐LA Study)

نویسندگان

  • Jonathan C. Hsu
  • Nitish Badhwar
  • Edward P. Gerstenfeld
  • Randall J. Lee
  • Mala C. Mandyam
  • Thomas A. Dewland
  • Kourtney E. Imburgia
  • Kurt S. Hoffmayer
  • Vasanth Vedantham
  • Byron K. Lee
  • Zian H. Tseng
  • Melvin M. Scheinman
  • Jeffrey E. Olgin
  • Gregory M. Marcus
چکیده

BACKGROUND Transseptal puncture is a critical step in achieving left atrial (LA) access for a variety of cardiac procedures. Although the mechanical Brockenbrough needle has historically been used for this procedure, a needle employing radiofrequency (RF) energy has more recently been approved for clinical use. We sought to investigate the comparative effectiveness of an RF versus conventional needle for transseptal LA access. METHODS AND RESULTS In this prospective, single-blinded, controlled trial, 72 patients were randomized in a 1:1 fashion to an RF versus conventional (BRK-1) transseptal needle. In an intention-to-treat analysis, the primary outcome was time required for transseptal LA access. Secondary outcomes included failure of the assigned needle, visible plastic dilator shavings from needle introduction, and any procedural complication. The median transseptal puncture time was 68% shorter using the RF needle compared with the conventional needle (2.3 minutes [interquartile range {IQR}, 1.7 to 3.8 minutes] versus 7.3 minutes [IQR, 2.7 to 14.1 minutes], P = 0.005). Failure to achieve transseptal LA access with the assigned needle was less common using the RF versus conventional needle (0/36 [0%] versus 10/36 [27.8%], P < 0.001). Plastic shavings were grossly visible after needle advancement through the dilator and sheath in 0 (0%) RF needle cases and 12 (33.3%) conventional needle cases (P < 0.001). There were no differences in procedural complications (1/36 [2.8%] versus 1/36 [2.8%]). CONCLUSIONS Use of an RF needle resulted in shorter time to transseptal LA access, less failure in achieving transseptal LA access, and fewer visible plastic shavings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of a radiofrequency needle improves the safety and efficacy of transseptal puncture for atrial fibrillation ablation.

BACKGROUND Atrial fibrillation (AF) ablation requires transseptal puncture to gain entry to the left atrium (LA). On rare occasions, LA entry cannot be achieved or cardiac perforation results in pericardial tamponade. OBJECTIVE This study sought to compare a new radiofrequency (RF) transseptal needle with the standard needle. METHODS We evaluated 1,550 AF ablations in 1,167 patients. We com...

متن کامل

Different transseptal puncture for different procedures: Optimization of left atrial catheterization guided by transesophageal echocardiography

BACKGROUND Left atrial catheterization through transseptal puncture is frequently performed in cardiac catheterization procedures. Appropriate transseptal puncture is critical to achieve procedural success. AIMS The aim of the study is to evaluate the feasibility of selective transseptal punctures, using a modified radiofrequency (RF) transseptal needle and transesophageal echocardiography (T...

متن کامل

NRG™ RF powered transseptal needle: a useful technique for transcatheter atrial septostomy and Fontan fenestration: report of three cases.

Transseptal puncture (TSP) is a frequently performed procedure for gaining access to the left atrium for catheter ablation, hemodynamic assessment of the left heart, left ventricular assist device implantation, percutaneous left atrial appendage closure or mitral valvuloplasty during childhood and adulthood. The standard technique for transseptal puncture applies mechanical pressure on the foss...

متن کامل

Radiofrequency perforation and conventional needle percutaneous transseptal left heart access: pathological features.

Perforating radiofrequency (PRF) energy has been used to obtain percutaneous transseptal left heart access. Contrary to ablative radiofrequency (RF), myocardial tissue responses to PRF thermal injury are incompletely defined. In this study, a newly developed RF catheter system for transseptal left atrial entry was compared with conventional needle puncture. Of 15 piglets having transfemoral car...

متن کامل

Radiofrequency puncture of the fossa ovalis for resistant transseptal access.

BACKGROUND Transseptal puncture with a conventional mechanical technique can fail because of a resistant interatrial septum. We evaluated the efficacy and safety of a new method to cross-resistant septae by transmitting radiofrequency (RF) energy through the transseptal needle. METHODS AND RESULTS Among 269 consecutive transseptal punctures, 13 (5%) were unsuccessful in 12 different patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2013