SCIENTIFIC REPORT Improving the repeatability of Heidelberg retina tomograph and Heidelberg retina tomograph II rim area measurements

نویسندگان

  • N G Strouthidis
  • D F Garway-Heath
چکیده

Aims: To devise and test strategies for improving Heidelberg retina tomograph (HRT and HRT-II) rim area (RA) repeatability and assess the benefit of the strategies in time series of HRT images. Methods: The effect of the standard and 320 mm reference planes and image quality on RA repeatability was assessed in a test-retest HRT image dataset from 74 subjects. A longitudinal HRT image dataset from 30 ocular hypertensive subjects was analysed by linear regression of RA over time, with each of the reference planes and using a manual image alignment facility. RA variability was estimated by comparing the standard deviation of residuals (RSD) generated by each linear regression. Results: RA repeatability was better with the 320 mm reference plane (repeatability coefficient 0.17 mm), improving further with only good quality images (repeatability coefficient 0.08 mm). For the longitudinal data, a significant (p,0.0001) reduction in the RSD from 0.10 to 0.05 mm was obtained with the 320 mm reference plane. Manual alignment led to a further significant (p,0.0001) reduction in the RSD to 0.04 mm. Conclusions: The findings support the use of a 320 mm reference plane and manual image alignment to analyse RA over time. The estimates of RA repeatability may be used to define thresholds for glaucomatous change.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the repeatability of Heidelberg retina tomograph and Heidelberg retina tomograph II rim area measurements.

AIMS To devise and test strategies for improving Heidelberg retina tomograph (HRT and HRT-II) rim area (RA) repeatability and assess the benefit of the strategies in time series of HRT images. METHODS The effect of the standard and 320 microm reference planes and image quality on RA repeatability was assessed in a test-retest HRT image dataset from 74 subjects. A longitudinal HRT image datase...

متن کامل

Factors affecting the variability of the Heidelberg Retina Tomograph III measurements in newly diagnosed glaucoma patients.

PURPOSE To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were exc...

متن کامل

Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurements.

AIMS To evaluate the test-retest variability of stereometric parameter measurements made with the Heidelberg retina tomograph (HRT) and Heidelberg retina tomograph-II (HRT-II), and to establish which parameter(s) provided the most repeatable and reliable measurements with both devices. An investigation into the factors affecting the repeatability of the measurements of this parameter(s) was con...

متن کامل

Comparison of Neuroretinal Rim Area Measurements Made by the Heidelberg Retina Tomograph I and the Heidelberg Retina Tomograph II

PURPOSE To investigate the agreement between neuroretinal rim area (RA) measurements using the Heidelberg Retina Tomograph I (HRT Classic) and Heidelberg Retina Tomograph II (HRT II). To compare apparent RA changes in follow-up series of HRT II topographies when using either an HRT Classic or HRT II mean topography as baseline. DESIGN Cross-sectional study and "no-change," short time series s...

متن کامل

Optic disc measurements using the Heidelberg Retina Tomograph in amblyopia

PURPOSE To investigate the characteristics of optic disc parameters in amblyopic eyes in which retinal involvement is uncertain. METHODS A total of 44 patients with a history of unilateral amblyopia (27 patients with persistent amblyopia and 17 patients with resolved amblyopia) were examined using the Heidelberg Retina Tomograph (HRT) II. Parameters examined included disc area, cup area, cup ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005