Laser-cured fibrinogen glue to repair bleb leaks in rabbits.

نویسندگان

  • M M Wright
  • E A Brown
  • K Maxwell
  • J D Cameron
  • A W Walsh
چکیده

OBJECTIVE To determine whether laser-cured fibrinogen glue can close bleb leaks in rabbits. METHODS Full-thickness filtration surgery with intraoperative mitomycin and a sutured limbus-based conjunctival flap was performed in 1 eye each of 19 New Zealand albino rabbits. On the second postoperative day, a 2- to 3-mm hole was made in the bleb. In 9 rabbits, the hole was glued using fibrinogen glue with indocyanine green dye added. The glue was "cured" with a diode laser. Eyes that had been glued and developed a subsequent leak had the glue reapplied on the day the leak was detected. RESULTS The glue remained on the conjunctiva for an average (mean+/-SD) of 1.9+/-1.8 days (range, 0-5 days). The last day of bleb leak for the rabbits with glued eyes was 1.6+/-2.4 days; for the control rabbits, it was 8.0+/-4.4 days (P=.001, Mann-Whitney U test). CONCLUSION Laser-cured fibrinogen glue is effective in closing bleb leaks in rabbits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PREPARATION OF FIBRIN GLUE AS A BIOLOGICAL SEALANT TO CONTROL BLEEDING IN HEART MUSCLE AND BLOOD VESSELS

Fibrin glue is used for control of bleeding in various surgical procedures. In this work the ability of fibrin glue to seal punctures in the vascular system is demonstrated. Blood samples were taken from rabbits, fibrinogen was separated and fibrin glue was eventually prepared. The rabbits were anesthetized and a midline incision was carried out. The heart and abdominal aorta were exposed. ...

متن کامل

Use of biological glue to control pulmonary air leaks.

Biological glue is a natural adhesive generated by the interaction between fibrinogen (pre-glue) and thrombin to produce fibrin. The pre-glue is prepared from a single donor (to avoid the problems of pooled plasma) and stored as cryoprecipitate. Before being used it is thawed, dissolved in saline, and activated into an adhesive by the addition of topical thrombin. Biological glue was used proph...

متن کامل

[The use of fibrin glue for the repair of experimental nasal CSF leak in rats].

Surgical repair of cerebrospinal fluid (CSF) leak requires the production of a seal competent to resist CSF pressure during the period of healing. Direct suturing, packing with muscle and fat grafts, and coverage with mucosal or muscle flaps have been effective in repairing most CSF leaks. Fibrin glue will improve the results of a CSF leak repair by providing better adhesion of the graft and im...

متن کامل

Mitotic effect of autologous blood injection and diode laser bleb revision on rabbit filtration blebs.

OBJECTIVE To investigate the effect of intrableb autologous blood injection and diode laser bleb revision on cellular proliferation in filtration blebs of rabbits. METHODS Bilateral filtration surgery with mitomycin was performed on 19 white 2.5- to 3-kg New Zealand rabbits. Autologous blood injection (n = 9) or diode laser bleb revision (n = 10) was performed on blebs of right eyes (interven...

متن کامل

Fibrinogen, riboflavin, and UVA to immobilize a corneal flap--conditions for tissue adhesion.

PURPOSE Laser-assisted in situ keratomileus (LASIK) creates a permanent flap that remains non-attached to the underlying laser-modified stroma. This lack of permanent adhesion is a liability. To immobilize a corneal flap, a protocol using fibrinogen (FIB), riboflavin (RF), and ultraviolet (UVA) light (FIB+RF+UVA) was devised to re-adhere the flap to the stroma. METHODS A model flap was create...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 116 2  شماره 

صفحات  -

تاریخ انتشار 1998