A simple and accurate dosimetry protocol to estimate activity for hyperthyroidism treatment.
نویسندگان
چکیده
BACKGROUND Aim of the study was to evaluate accuracy of different dosimetry protocols in estimating the required 131I activity to treat hyperthyroid patients. MATERIALS AND METHODS Forty consecutive patients were analysed: twenty-eight Graves' disease; twelve autonomous thyroid nodule (ATN). Maximum-uptake, effective half-time and residence-time were estimated from Radioiodine Uptake Test. Residence-time was estimated using a bi-compartmental model. For 131I activity calculation, algorithms laid down in European Association of Nuclear Medicine (EANM) guidelines, ICRP 53 approach and a mono-exponential formula (ME), were compared with OLINDA/EXM results. RESULTS Based on EANM guidelines, activities to be administered were 3% higher in Graves' disease (p = 0.001) and 3% higher in ATN (p = 0.046). Calculated activities using ICRP 53 approach were significantly lower compared to OLINDA/EXM: 33% in Graves' disease; 17% in ATN. Activities recommended by ME, were significantly higher: in Graves' disease 20%; 42% in ATN. CONCLUSIONS Only EANM algorithm predict quite well, compared to OLINDA/EXM, the required activity to treat hyperthyroid patients.
منابع مشابه
I-124 pre-therapy dosimetry for the treatment of differentiated thyroid cancer: A single center experience
Introduction:The maximum tolerable activity (MTA) of I-131 in radioiodine therapy is an established surrogate quantity to ensure that the therapeutic activity does not produce severe damages to the bone marrow and lung. The aim of this study was to estimate the MTAs for high-risk patients using I-124 pre-therapy dosimetry and to compare the results with published literature. <...
متن کاملدزیمتری in-vivo در پرتودرمانی خارجی تومورهای مغزی تحت درمان با فوتون MV15 با استفاده از فیلم گاف کرومیک EBT3
Background and purpose: In-vivo dosimetry is used to ensure accurate delivery of dose to tumors during radiotherapy. This study aimed at measuring the entrance doses without the build-up cap for patients undergoing 15MV radiotherapy and determining the percentage errors between doses measured by films and those calculated with a treatment planning system (TPS). Materials and methods: The stu...
متن کاملRecent developments in brachytherapy source dosimetry
Application of radioactive isotopes is the treatment of choice around the globe for many cancer sites. In this technique, the accuracy of the radiation delivery is highly dependent on the accuracy of radiation dosimetry around individual brachytherapy sources. Moreover, in order to have compatible clinical results, an identical method of source dosimetry must be employed across the world. This ...
متن کاملAssessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...
متن کاملDeveloping a Verification and Training Phantom for Gynecological Brachytherapy System
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nuclear medicine review. Central & Eastern Europe
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2015