Creatine kinase B-subunit activity in serum after immunoinhibition of M-subunit activity.

نویسندگان

  • W Gerhardt
  • J Waldenström
چکیده

Creatine kinase (EC 2.7.3.2) B-subunit activity in serum may be routinely measured as residual activity after specific immunoinhibition of the M-subunit. We assessed the inhibition kinetics, specificity, completeness of inhibition, and inhibitory capacity of three different anti-M preparations, with use of isolated human BB, MM, and MB isoenzymes. The Scandinavian-recommended reaction system was used. We suggest a set of tentative quality requirements for anti-M for use in diagnosing acute myocardial infarction. The need to measure and subtract sample residual adenylate kinase activity was demosntrated. We describe a routine photometric method for determining B-subunit activity in serum. With the Scandinavian CK method the upper reference value for total creatine kinase in serum was found to be 150 U/L for women, 270 U/L for men. By bioluminescence, we found the upper reference value for B-subunit activity to be 6 U/L for both sexes. We discuss three different modes for applying B-subunit determinations to the diagnosis of acute myocardial infarction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Creatine kinase and creatine kinase B-subunit activity in serum in cases of suspected myocardial infarction.

We evaluated a diagnostic strategy by studying 481 patients suspected of having had an acute myocardial infarction; the prevalence of infarction by independent criteria was 0.43. This strategy is based on the sequential application of: (a) clinical criteria; (b) total creatine kinase determinations in two serum samples drawn within 10 to 20 h of the onset of acute symptoms; and (c) creatine kin...

متن کامل

An immunoinhibition assay for determination of creatine kinase isoforms in serum.

We report a preliminary evaluation of an immunoinhibition assay for creatine kinase isoform quantification. The procedure employs the monoclonal antibody CKM-G01, which inhibits the native M subunit of creatine kinase. The antibody does not inhibit the M subunit modified by removal of lysine by plasma carboxypeptidase N. Residual activity after treatment with the antibody is therefore due to se...

متن کامل

Optimized bioluminescence assay of creatine kinase and creatine kinase B-subunit activity.

Spectrophotometry of CK-B subunit activity based on immunoinhibition is rapid and convenient. However, the low sensitivity limits clinical applications to serum samples with CK-B activities considerably above normal. A sensitive, but not optimized, bioluminescent assay of CK-B, also based on immunoinhibition, has been described. We improved this method by the use of an ADP concentration saturat...

متن کامل

Clinical evaluation of immunoinhibition determination of creatine kinase B subunits in coronary care.

One hundred patients with chest pain of cardiac origin were evaluated on the basis of clinical findings, electrocardiograph results, and total creatine kinase (CK) and creatine kinase B-subunit (CK-B) activity (as determined by immunoinhibition with the Boehringer CK-MB kit) in serum. All patients diagnosed as having had an acute myocardial infarction had increased values for both CK-B and tota...

متن کامل

A macro creatine kinase isoenzyme in serum of apparently healthy individuals.

Activity of creatine kinase B subunit, as measured by an immunoinhibition assay, is persistently increased in certain healthy, asymptomatic adults, whose values for total CK activity are within normal limits. Serum samples from two such individuals were investigated by electrophoresis, heat inactivation, determination of activation energies, and immunosorption (on protein A). The results demons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 7  شماره 

صفحات  -

تاریخ انتشار 1979