Duration of Heart Failure Is an Important Predictor of Outcomes After Mechanical Circulatory Support.
نویسندگان
چکیده
BACKGROUND Heart failure (HF) progression results in worsening functional capacity and end-organ compromise. HF may occur acutely or be associated with a chronic presentation. We hypothesized that the duration of HF affects outcomes after mechanical circulatory support. METHODS AND RESULTS A total of 10 730 patients registered in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) who received primary implant of a mechanical circulatory support device were stratified according to the duration of HF symptoms: acute HF (AHF; ≤1 month), sub-AHF (1-12 months), and chronic HF (Cr-HF; ≥ 12 months). AHF patients were younger with a higher proportion of women and white and with a lower prevalence of peripheral vascular disease and history of prior cardiac surgeries. Sixty percent of AHF patients were INTERMACS profile 1 at the time of implantation versus 24% and 13.2% in the sub-AHF and Cr-HF groups, respectively (P=0.0001). Patients with AHF had the highest utilization of biventricular support (14.4%). The estimated survival at 4 years was 58%, 51%, and 45% for the AHF, sub-AHF, and Cr-HF patients (P=0.006). The proportion of patients with AHF who received heart transplantation at 1 year was 29% compared with 22.6% in the patients with Cr-HF. After adjustment for known risk factors of adverse outcome, patients with AHF have a better late phase prognosis compared with patients with Cr-HF (hazard ratio, 0.34; P=0.0003). CONCLUSIONS The duration of HF before durable mechanical circulatory support implant is an important variable influencing outcome. Patients with AHF had improved survival at 4 years and higher rates of transplantation at 1 year despite higher acuity of presentation.
منابع مشابه
Mechanical circulatory support: registering a therapy in evolution.
The development of durable mechanical circulatory support systems paralleled the expansion of cardiac transplantation. The National Institutes of Health sponsored grants in the 1980s to develop implantable left heart assist systems; 20 years later, they contracted for a national registry, the Interagency Registry for Mechanical Assisted Circulatory Support, to track the clinical evolution of th...
متن کاملAdvances in Heart Failure Mechanical Circulatory Support Registering a Therapy in Evolution
The development of durable mechanical circulatory support systems paralleled the expansion of cardiac transplantation. The National Institutes of Health sponsored grants in the 1980s to develop implantable left heart assist systems; 20 years later, they contracted for a national registry, the Interagency Registry for Mechanical Assisted Circulatory Support, to track the clinical evolution of th...
متن کاملRegistering a Therapy in Evolution
The development of durable mechanical circulatory support systems paralleled the expansion of cardiac transplantation. The National Institutes of Health sponsored grants in the 1980s to develop implantable left heart assist systems; 20 years later, they contracted for a national registry, the Interagency Registry for Mechanical Assisted Circulatory Support, to track the clinical evolution of th...
متن کاملنتایج کاربرد بالون پمپ داخل آئورت در بیماران جراحی قلبIntra-Aortic Ballon Pump Outcome in Cardiac Surgical Patients
Background & Aim: Intra-aortic ballon pump(IABP) is a mechanical device that has become an accepted treatment modality for patients with severely compromised hemodynamics. The present retrospective study was undertaken to identify the major survival and nonsurvival determinants of patients who were in need of intra-aortic ballon pump support after cardiac surgery. Patients & Methods: Th...
متن کاملOutcomes of patients with peripartum cardiomyopathy who received mechanical circulatory support. Data from the Interagency Registry for Mechanically Assisted Circulatory Support.
BACKGROUND We describe the characteristics and outcomes of peripartum cardiomyopathy (PPCMP) patients who received durable mechanical circulatory support and compared it with other etiologies of advanced heart failure. METHODS AND RESULTS We analyzed 1258 women who were registered in Interagency Registry for Mechanically Assisted Circulatory Support between June 2006 and March 2012. Baseline ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Heart failure
دوره 8 5 شماره
صفحات -
تاریخ انتشار 2015