Microvascular pressure and functional capillary density in extreme hemodilution with low- and high-viscosity dextran and a low-viscosity Hb-based O2 carrier.
نویسندگان
چکیده
Blood losses are usually corrected initially by the restitution of volume with plasma expanders and subsequently by the restoration of oxygen-carrying capacity using either a blood transfusion or possibly, in the near future, oxygen-carrying plasma expanders. The present study was carried out to test the hypothesis that high-plasma viscosity hemodilution maintains perfused functional capillary density (FCD) by preserving capillary pressure. Microvascular pressure responses to extreme hemodilution with low- (LV) and high-viscosity (HV) plasma expanders and an exchange transfusion with a polymerized bovine cell-free Hb (PBH) solution were analyzed in the awake hamster window chamber model (n = 26). Systemic hematocrit was reduced from 50% to 11%. PBH produced a greater mean arterial blood pressure than the nonoxygen carriers. FCD was higher after a HV plasma expander (70 +/- 15%) vs. PBH (47 +/- 12%). Microvascular pressure spanning the capillary network was higher after a HV plasma expander (16-19 mmHg) compared with PBH (12-16 mmHg) and a LV plasma expander (11-14 mmHg) but lower than control (22-26 mmHg). FCD was found to be directly proportional to capillary pressure. The use of a HV plasma expander in extreme hemodilution maintained the number of perfused capillaries and tissue perfusion by comparison with a LV plasma expander due to increased mean arterial blood pressure and capillary pressure. The use of PBH increased mean arterial pressure but reduced capillary pressure due to vasoconstriction and did not maintain FCD.
منابع مشابه
Alginate plasma expander maintains perfusion and plasma viscosity during extreme hemodilution.
Extreme hemodilution was performed in the hamster chamber window model using 6% Dextran 70, lowering systemic hematocrit by 60%. Animals were subsequently divided into three groups and hemodiluted to a hematocrit of 11% using 6% Dextran 70, 6% Dextran 500, and a 4% Dextran 70 + 0.7% alginate solution (n = 6 each group). Final plasma viscosities were 1.4 +/- 0.2, 2.2 +/- 0.1, and 2.7 +/- 0.2 cp,...
متن کاملPlasma viscosity regulates systemic and microvascular perfusion during acute extreme anemic conditions.
The hamster window chamber model was used to study systemic and microvascular hemodynamic responses to extreme hemodilution with low- and high-viscosity plasma expanders (LVPE and HVPE, respectively) to determine whether plasma viscosity is a factor in homeostasis during extreme anemic conditions. Moderated hemodilution was induced by two isovolemic steps performed with 6% 70-kDa dextran until ...
متن کاملBlood viscosity maintains microvascular conditions during normovolemic anemia independent of blood oxygen-carrying capacity.
Responses to exchange transfusion with red blood cells (RBCs) containing methemoglobin (MetRBC) were studied in an acute isovolemic hemodiluted hamster window chamber model to determine whether oxygen content participates in the regulation of systemic and microvascular conditions during extreme hemodilution. Two isovolemic hemodilution steps were performed with 6% dextran 70 kDa (Dex70) until s...
متن کاملPlasma viscosity regulates capillary perfusion during extreme hemodilution in hamster skinfold model.
Effect of increasing blood viscosity during extreme hemodilution on capillary perfusion and tissue oxygenation was investigated in the awake hamster skinfold model. Two isovolemic hemodilution steps were performed with 6% Dextran 70 [molecular weight (MW) = 70,000] until systemic hematocrit (Hct) was reduced by 65%. A third step reduced Hct by 75% and was performed with the same solution [low v...
متن کاملTissue oxygenation after exchange transfusion with ultrahigh-molecular-weight tense- and relaxed-state polymerized bovine hemoglobins.
Hemoglobin (Hb)-based O(2) carriers (HBOCs) constitute a class of therapeutic agents designed to correct the O(2) deficit under conditions of anemia and traumatic blood loss. The O(2) transport capacity of ultrahigh-molecular-weight bovine Hb polymers (PolybHb), polymerized in the tense (T) state and relaxed (R) state, were investigated in the hamster chamber window model using microvascular me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 287 1 شماره
صفحات -
تاریخ انتشار 2004