Intrinsic uniformity and relative sensitivity quality control tests for single-head gamma cameras.

نویسندگان

  • A A Elkamhawy
  • J R Rothenbach
  • S Damaraju
  • S M Badruddin
چکیده

OBJECTIVE We sought to determine the best parameters for rapid performance of daily quality control testing of intrinsic uniformity and relative sensitivity for the single-head gamma-camera system in our nuclear medicine department. METHODS The effects of the following parameters on intrinsic uniformity were studied: gamma source activity, number of acquired counts for the flood image, source-to-camera distance, image matrix size, and source volume. The dead time of the system was determined experimentally using the two-source method for accurate calculation of relative sensitivity. RESULTS A set of parameters for rapid performance of daily gamma-camera intrinsic uniformity and relative sensitivity was determined. The dead time of our gamma-camera system was found to be 4.5 +/- 0.2 micros. CONCLUSION With our recommended parameters, the intrinsic uniformity and relative sensitivity quality control testing can be performed in 5-6 min. The dead time of each gamma-camera system must be determined experimentally in each nuclear medicine department.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the Geometrical and Physical Fluctuations While Performing Intrinsic Uniformity Test for Philips Forte Gamma Camera

Intrinsic flood field uniformity is a fundamental quality control test that is considered as prerequisite for performing clinical routine exams using the gamma camera. Every gamma camera vendor provides recommended geometrical and physical parameters that should be followed while performing this test. Conventional methods using NEMA recommended parameters also can be used as well. The aim of th...

متن کامل

Observed intercamera variability in clinically relevant performance characteristics for Siemens Symbia gamma cameras

We conducted an evaluation of the intercamera (i.e., between cameras) variability in clinically relevant performance characteristics for Symbia gamma cameras (Siemens Medical Solutions, Malvern, PA) based on measurements made using nine separate systems. The significance of the observed intercamera variability was determined by comparing it to the intracamera (i.e., within a single camera) vari...

متن کامل

Quality Control of Scintillation Cameras (Planar and SPECT)

The purpose of quality control (QC) is to detect changes in the performance of a gamma camera system that may adversely affect the interpretation of clinical studies. Clearly, there are a large number of factors that contribute to the final image quality, including uniformity, resolution (both intrinsic and energy), collimation and the hard copy device. In addition, for certain types of studies...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Comparison of acceptance tests for SPECT systems in Tehran [Persian]

Introduction: Acceptance test is a necessary procedure after SPECT system installation. The goal of this test is to reveal system's present condition, to compare it with manufacturer's specifications and also as a base for later tests. Methods: This study investigated four SPECT systems in Tehran. All of the quality control tests are performed on the basis of NEMA and IAEA recommendations...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 2000