Repeatability of Colour Reading with a Clinical and a Laboratory Spectrophotometer
نویسندگان
چکیده
Corresponding Author: Dr. Gabriele Corciolani, Via Derna 4, 58100 Grosseto (Italy) E-mail: [email protected]; Tel/Fax: +39056425384 Abstract Objectives: The aim of this study was to evaluate the repeatability of readings with a clinical spectrophotometer in comparison with a laboratory one. Materials and Methods: A stand alone clinical spectrophotometer (Easyshade, Vita) and a laboratory one (PSD1000, Ocean Optics) were evaluated. Five ceramic disks were produced in different layering, with a fixed total thickness of the samples being maintained. Metal disks of 15mm in diameter and 0.7mm thickness were cast. The ceramic system used for layering was Omega 900 (Vita), and the colour selected for the trial was A3. The colour evaluation of each sample was repeated 5 times with each spectrophotometer to verify the scanning repeatability. The spectrophotometer repeatability was statistically evaluated analyzing the coefficient of variation (CV), which represents the ratio of the standard deviation to the mean of the CIELab* colour values. Results: An excellent scanning repeatability for both the spectrophotometers tested was demonstrated. Very low values of the coefficient of variation (0,002<CV<0,111) were obtained for Ocean Optics PSD1000 as well as for Easyshade, by both fixing the handpiece of the device to a graded stand (0<CV<0,022) and holding it by hand (0,008<CV<0,913). Discussion: Although manufacturing differences do not allow a direct comparison to be made between the two instruments tested, the reading values obtained from the tests showed an excellent scanning repeatability, both for the clinical spectrophotometer (Easyshade) and for the laboratory one (PSD1000). Conclusions: The repeatability of the readings with the clinical device were acceptable and comparable to the laboratory one and it can therefore be considered reliable. However, further studies are necessary to verify the exact connection between the colour values obtained from the clinical spectrophotometer and the absolute CIELab* values specific for each shade.
منابع مشابه
Measuring Human Skin Colour
Human skin colour measurements from four ethnic groups including 188 subjects were accumulated. Five to ten locations of each subject were measured by using two different instruments, a tele-spectroradiometer and a spectrophotometer. Three repeated measurements were accumulated for each location. Repeatability of the measurements at different locations from different ethnicities was examined us...
متن کاملTo Develop a Simple (UV-VIS Spectrometric) Method for the Estimation of Multivitamin with Special Reference to Capsules & Tablets
Fat-soluble vitamin regulation is of particular significance in cystic fibrosis. A vitamin is an organic compound required as a nutrient in tiny amounts by an organism. In the present study, we had developed a simple method to estimate the fat soluble vitamin by Spectrophotometer. The vitamin A, D, E and K were estimated by spectrophotometer at 325 nm, 264 nm, 525 nm and 635 nm respectively. Af...
متن کاملA photoelectric spectrophotometer suitable for the measurement of vitamin A by the antimony-trichloride reaction.
The measurement by visual methods of the fleeting blue colour of vitamin A in the antimony-trichloride reaction presents considerable difficulties which can be largely overcome by the use of photoelectric methods with corresponding increase in accuracy. The photoelectric spectrophotometer now described was constructed in I 941 when no comparable instrument of this type was commercially availabl...
متن کاملA direct-reading bilirubinometer incorporating hemolysis and turbidity correction.
An instrument has been developed by which the bilirubin concentration in serum is determined spectrophotometrically.A readingof the difference in absorbanceat450me and 540 m is obtained. The presenceof hemoglobinor turbidity is corrected for, so that the differential absorbancereading, multiplied by a calibration factor, gives the correct bilirubin concentration. Comparisonswith analysesusinga ...
متن کاملCapillarys 3 Octa®: Analytical Performance Assessment for HbA1c Quantification
Objective: Determination of HbA1c level is a precious indicator for therapeutic follow-up of patients with type 1 or type 2 diabetes. Our study aimed to evaluate the analytical characteristics of Capillarys 3 Octa® HbA1c measurement by capillary electrophoresis. Materials and Methods: Our study involved 265 venous whole blood specimens repeatability, intermediate fidelity, accuracy, linearity,...
متن کامل