SU-E-T-319: Monte Carlo Characterization of a New Directional Pd-103 High Dose Rate Source for Brachytherapy Application.

نویسندگان

  • A Heredia
  • A Robinson
  • D Henderson
  • B Thomadsen
چکیده

PURPOSE Standard brachytherapy sources emit radiation in a non-preferential direction away from the source. Though treatment outcomes are good, this can lead to late skin and subcutaneous toxicities in sensitive structures. Proposed low dose rate directional sources for interstitial brachytherapy, showed to have an improvement in the dose uniformity within the subcutaneous volume, reduction in skin dose, and reduction in volume receiving dose outside the target. The objective of this work is to demonstrate the potential use of a new Pd-103 directional seed for application in high dose rate brachytherapy treatments. METHODS Monte Carlo simulations were performed using the MCNP5 F6 energy deposition tallies as well as the MCNP5 F4 flux density tallies placed around a partially shielded Pd-103 source at angles(deg): 0, 45, 90, 135, 180, 225, 270, 315 as well as radial distances (cm): 0.5, 1, 1.5, 2, 3, 4, 5, 6, 7, 8, 9, 10. The source that modeled was a Pd-103 core using TG-43U recommended nuclear data, with a diameter = 1.4 mm, active length = 1.0 cm. In addition osmium metal with .03 mm thickness was used as shielding material to cover half of the cylindrical surface of the Pd-103 volume. The seed was encapsulated using .05 mm thick titanium. RESULTS MCNP models show that the dose to the radial distances, corresponding to the osmium shielded side, are dramatically reduced to less than 4% of the total dose. CONCLUSIONS The potential of a Pd-103 directional brachytherapy source has been studied. The results show that a seed with a partially shielded volume can be exploited to reduce side effects associated with radiation therapy to sensitive structures surrounding target volumes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric characterization of a high dose rate 192I source for brachytherapy application using Monte Carlo simulation and benchmarking with thermoluminescent dosimetry

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

متن کامل

Experimental and Monte Carlo dosimetric characterization of a 1 cm (103)Pd brachytherapy source.

PURPOSE To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of a new elongated (103)Pd brachytherapy source through both experimental measurements and Monte Carlo (MC) simulations. Measured and MC-calculated dose distributions were used to determine the American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters for t...

متن کامل

Determination of Dosimetric characteristics of a New 192Ir-PDR Brachytherapy Source According to AAPM TG- 43 Protocol using Monte Carlo simulation technique

Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...

متن کامل

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...

متن کامل

Monte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources

Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part14  شماره 

صفحات  -

تاریخ انتشار 2012