Superresolution microscope image reconstruction by spatiotemporal object decomposition and association: application in resolving t-tubule structure in skeletal muscle.

نویسندگان

  • Mingzhai Sun
  • Jiaqing Huang
  • Filiz Bunyak
  • Kristyn Gumpper
  • Gejing De
  • Matthew Sermersheim
  • George Liu
  • Pei-Hui Lin
  • Kannappan Palaniappan
  • Jianjie Ma
چکیده

One key factor that limits resolution of single-molecule superresolution microscopy relates to the localization accuracy of the activated emitters, which is usually deteriorated by two factors. One originates from the background noise due to out-of-focus signals, sample auto-fluorescence, and camera acquisition noise; and the other is due to the low photon count of emitters at a single frame. With fast acquisition rate, the activated emitters can last multiple frames before they transiently switch off or permanently bleach. Effectively incorporating the temporal information of these emitters is critical to improve the spatial resolution. However, majority of the existing reconstruction algorithms locate the emitters frame by frame, discarding or underusing the temporal information. Here we present a new image reconstruction algorithm based on tracklets, short trajectories of the same objects. We improve the localization accuracy by associating the same emitters from multiple frames to form tracklets and by aggregating signals to enhance the signal to noise ratio. We also introduce a weighted mean-shift algorithm (WMS) to automatically detect the number of modes (emitters) in overlapping regions of tracklets so that not only well-separated single emitters but also individual emitters within multi-emitter groups can be identified and tracked. In combination with a maximum likelihood estimator method (MLE), we are able to resolve low to medium density of overlapping emitters with improved localization accuracy. We evaluate the performance of our method with both synthetic and experimental data, and show that the tracklet-based reconstruction is superior in localization accuracy, particularly for weak signals embedded in a strong background. Using this method, for the first time, we resolve the transverse tubule structure of the mammalian skeletal muscle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Superresolution Structured Illumination Microscopy (SR-SIM)

How Superresolution with ELYRA S.1 works The resolving power of a light microscope is limited to approximately 200nm in the lateral (XY) and 500nm in the axial (Z) direction. This so-called diffraction limit has been fi rst described by Ernst Abbe in 1873 (reference 1) and still holds true today. In simple terms, it posits that objects cannot be resolved with a conventional light microscope if ...

متن کامل

Calcium Release Domains in Mammalian Skeletal Muscle Studied with Two-photon Imaging and Spot Detection Techniques

The spatiotemporal characteristics of the Ca(2+) release process in mouse skeletal muscle were investigated in enzymatically dissociated fibers from flexor digitorum brevis (FDB) muscles, using a custom-made two-photon microscope with laser scanning imaging (TPLSM) and spot detection capabilities. A two-microelectrode configuration was used to electrically stimulate the muscle fibers, to record...

متن کامل

Genome-wide Association Study to Identify Genes and Biological Pathways Associated with Type Traits in Cattle using Pathway Analysis

Extended Abstract Introduction and Objective: Type traits describing the skeletal characteristics of an animal are moderately to strongly genetically correlate with other economically important traits in cattle including fertility, longevity and carcass traits. The present study aimed to conduct a genome wide association studies (GWAS) based on gene-set enrichment analysis for identifying the ...

متن کامل

A Novel Approach of Beam Surf Algorithm for View and Illumination Invariant Image Matching Based on Super-Resolution image Reconstruction

In this paper, we address a super-resolution Reconstruction problem of generating a high-resolution image from low-resolution images. The proposed superresolution method consists of three steps: image registration, singular value decomposition (SVD)-based image fusion and interpolation is a part of beam surf algorithm. The contribution of this work is two-fold. First we customize an image regis...

متن کامل

Automated Tumor Segmentation Based on Hidden Markov Classifier using Singular Value Decomposition Feature Extraction in Brain MR images

ntroduction: Diagnosing brain tumor is not always easy for doctors, and existence of an assistant that                                                      facilitates the interpretation process is an asset in the clinic. Computer vision techniques are devised to aid the clinic in detecting tumors based on a database of tumor c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 2014