Long-term surgical outcomes of porous polyethylene orbital implants: a review of 314 cases
نویسندگان
چکیده
PURPOSE This study reports on the long-term surgical outcomes after the insertion of porous Medpor orbital implants into anophthalmic sockets. METHODS A retrospective chart review of 314 eyes from 314 patients who underwent evisceration, enucleation and secondary procedures using Medpor orbital implants was completed focusing on implant-associated complications and their corrective methods as surgical outcomes. RESULTS The mean follow-up was 50 months (range 6-107 months). The most common complication was blepharoptosis (n=33, 10.5%). Other postoperative complications were exposure (n=14, 4.5%) and implant infection (n=3, 1%). The complications were successfully managed by surgical repair and/or conservative care. CONCLUSION Using Medpor resulted in similar surgical outcomes, in terms of the types and frequencies of complications, as other kinds of porous orbital implants.
منابع مشابه
Long-term infectious complications of using porous polyethylene mesh for orbital fracture reconstruction
Porous polyethylene is a widely used implants in orbital reconstruction, on which comprehensive clinical analysis, various treatments, and different prognosis according to specific classification principles on long-term complications have not been reported.To investigate the new clinical symptoms, intraoperative findings, treatments, and outcomes of complications long period after previous surg...
متن کاملLong-term Surgical Outcomes of the Multi-purpose Conical Porous Synthetic Orbital Implant
PURPOSE We present clinical results of the use of the multipurpose conical porous synthetic orbital implant (MCOI) in surgical procedures of evisceration, enucleation, and secondary enucleation in ophthalmology patients. METHODS A retrospective review was performed of 59 eyes in which conical implants were used, including 36 cases of eviscerations, 11 enucleations, and 9 secondary enucleation...
متن کاملAutogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.
BACKGROUND Temporalis fascia has been recommended for hydroxyapatite sphere exposure. The aim of this study was to identify potential risk factors for exposure of porous polyethylene (Medpor) sphere implants and evaluate the use of autogenous temporalis fascia as a patch graft for exposure. METHODS A retrospective review of consecutive cases of porous polyethylene sphere orbital implant expos...
متن کاملDelayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports
BACKGROUND Porous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported. CASE PRESENTATION This is a retrospective review of clinical presentations, ra...
متن کاملThe Survival of Freely Grafted Orbital Fat on Porous Polyethylene Orbital Implants in the Rabbit
PURPOSE To investigate the long term survival of orbital fat grafted on a Medpor implant as a method of preventing porous polyethylene orbital implant (Medpor) exposure in anophthalmic sockets. METHODS In one orbit in each of 8 rabbits, a small amount of retrobulbar orbital fat was grafted between the anterior surface of the Medpor implant and overlying conjunctiva, during the enucleation and...
متن کامل