Allowable imprecision for laboratory tests based on clinical and analytical test outcome criteria.

نویسندگان

  • J O Westgard
  • J J Seehafer
  • P L Barry
چکیده

The allowable imprecision for laboratory tests has been estimated from criteria based on clinical and analytical test outcome. The analytical outcome criteria studied are the Clinical Laboratory Improvement Amendments (CLIA) criteria for proficiency testing. The clinical outcome criteria are estimates of medically significant changes in test results taken from a study in the literature. The estimates of allowable imprecision were obtained from quality-planning models that relate test outcome criteria to the allowable amount of imprecision and inaccuracy and to the quality control that is necessary to assure achievement of the desired outcome criteria in routine operation. These operating specifications for imprecision are consistently more demanding (require lower CVs) than the medically useful CVs originally recommended in the literature because the latter do not properly consider within-subject biological variation. In comparing estimates of allowable imprecision, the CLIA outcome criteria are more demanding than the clinical outcome criteria for aspartate aminotransferase (asymptomatic patients), cholesterol, creatinine (asymptomatic patients), glucose, thyroxine, total protein, urea nitrogen, hematocrit, and prothrombin time. The clinical outcome criteria are more demanding for bilirubin (acute illness), iron, potassium, urea nitrogen (acute illness), and leukocyte count. The estimates of allowable imprecision from analytical and clinical outcome criteria overlap for aspartate aminotransferase (acute illness), bilirubin (asymptomatic patients), calcium, creatinine (acute illness), sodium, triglyceride, and hemoglobin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

European specifications for imprecision and inaccuracy compared with operating specifications that assure the quality required by US CLIA proficiency-testing criteria.

Proposed and interim European quality specifications for imprecision and inaccuracy have been compared with the US CLIA total error criteria for proficiency testing (PT). To assess the relative demands of separate imprecision and inaccuracy specifications vs total error criteria, we derived the imprecision and inaccuracy that would be allowable if a testing process were to provide 90% assurance...

متن کامل

Analytical Goals for Point-of-Care Testing Used for Diabetes Management in Australian Health Care Settings Outside The Laboratory

Diabetes mellitus is a major global health problem. Pathology testing for hemoglobin A1c (HbA1c), lipids, and urine albumin/creatinine ratio (ACR) has an important role in the management of diabetes patients. Each of these markers can be performed by point-of-care testing (POCT). This article focuses on setting analytical goals (quality specifications) for the imprecision, bias, and total allow...

متن کامل

Cholesterol operational process specifications for assuring the quality required by CLIA proficiency testing.

Current U.S. governmental regulations and requirements for the quality of laboratory tests do not provide a consistent form, comparable numbers, or practical specifications for the routine operation of laboratory testing processes. For cholesterol, as an example, the Health Care Financing Administration provides an analytical performance criterion for proficiency testing to enforce the Clinical...

متن کامل

Influence of analytical and biological variation on the clinical interpretation of seminal parameters.

Quality assurance in semen analysis has been questioned recently in this journal. Based on the limited capacity of seminal parameter in the determination of fertility, the authors advocated abandoning methods of quality assurance in semen analysis for clinical situations. In this article, we explore arguments as to why quality assurance in semen analysis for clinical use is not 'a waste of time...

متن کامل

Proposal for the modification of the conventional model for establishing performance specifications.

Appropriate quality of test results is fundamental to the work of the medical laboratory. How to define the level of quality needed is a question that has been subject to much debate. Quality specifications have been defined based on criteria derived from the clinical applicability, validity of reference limits and reference change values, state-of-the-art performance, and other criteria, depen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 40 10  شماره 

صفحات  -

تاریخ انتشار 1994